2021•Al-Azhar International Medical Journal /Al-Azhar International Medical JournalOpen access

Comparative Study Between Intramedullary K Wires Versus Mini-plates and Screws in Fixation of Metacarpal Shaft Fractures in Adults

mahmoud abdel-hamid, Mohamed Ibrahim Abulsoud, Mohamed Mohamed Bissar

Open full text 9 citations

Abstract

Background: Percutaneous intramedullary K. wires fixation and mini-plates fixation are reasonable options for treating unstable metacarpal fractures as they provide anatomical reduction and rigid fixation, which is adequate to permit early mobilization. Objective: To compare between mini-plates and Kirschner wires in management of unstable metacarpal shaft fractures in adults. Patients and Methods: All patients (n=30) included in this prospective comparative study were managed and followed up at Al-Azhar University Hospital from January 2019 to February 2020. Thirty patients with fracture of shaft metacarpal were divided into 2 groups: group A (n=15) were managed by percutaneous intramedullary K-wires and group B (n=15) were managed by mini-plates. Results:27 Patients were males and 3 were females . Dominant hand affection were in 20 patients . All patients had a complete union between 4-8 weeks for group A with average of 6 weeks and 6-10 weeks for group B with average of 8 weeks. The total result according to TAF score, Quick DASH score, and handgrip was excellent in 10 cases, good in 4 cases, and fair in 1 case in group A, while group B was excellent in 10 cases, good in 3 cases, fair in 1 case and poor in 1 case. Conclusion: Both techniques are highly effective for fixation of metacarpal shaft fractures. Mini-plate fixation provides rapid recovery of hand function and K-wire fixation allows a wide range of hand motion and soft tissue preservation.

Open-access reader

About this research paper

What this paper is about

Background: Percutaneous intramedullary K. wires fixation and mini-plates fixation are reasonable options for treating unstable metacarpal fractures as they provide anatomical reduction and rigid fixation, which is adequate to permit early mobilization. Objective: To compare between mini-plates and Kirschner wires in management of unstable metacarpal shaft fractures in adults. Patients and Methods: All patients (n=30) included in this prospective comparative study were managed and followed up at Al-Azhar University Hospital from January 2019 to February 2020. Thirty patients with fracture of shaft metacarpal were divided into 2 groups: group A (n=15) were managed by percutaneous intramedullary K-wires and group B (n=15) were managed by mini-plates. Results:27 Patients were males and 3 were females . Dominant hand affection were in 20 patients . All patients had a complete union between 4-8 weeks for group A with average of 6 weeks and 6-10 weeks for group B with average of 8 weeks. The total result according to TAF score, Quick DASH score, and handgrip was excellent in 10 cases, good in 4 cases, and fair in 1 case in group A, while group B was excellent in 10 cases, good in 3 cases, fair in 1 case and poor in 1 case. Conclusion: Both techniques are highly effective for fixation of metacarpal shaft fractures. Mini-plate fixation provides rapid recovery of hand function and K-wire fixation allows a wide range of hand motion and soft tissue preservation.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Percutaneous intramedullary K. wires fixation and mini-plates fixation are reasonable options for treating unstable metacarpal fractures as they provide anatomical reduction and rigid fixation, which is adequate to permit early mobilization. Objective: To compare between mini-plates and Kirschner wires in management of unstable metacarpal shaft fractures in adults. Patients and Methods: All patients (n=30) included in this prospective comparative study were managed and followed up at Al-Azhar University Hospital from January 2019 to February 2020. Thirty patients with fracture of shaft metacarpal were divided into 2 groups: group A (n=15) were managed by percutaneous intramedullary K-wires and group B (n=15) were managed by mini-plates. Results:27 Patients were males and 3 were females . Dominant hand affection were in 20 patients . All patients had a complete union between 4-8 weeks for group A with average of 6 weeks and 6-10 weeks for group B with average of 8 weeks. The total result according to TAF score, Quick DASH score, and handgrip was excellent in 10 cases, good in 4 cases, and fair in 1 case in group A, while group B was excellent in 10 cases, good in 3 cases, fair in 1 case and poor in 1 case. Conclusion: Both techniques are highly effective for fixation of metacarpal shaft fractures. Mini-plate fixation provides rapid recovery of hand function and K-wire fixation allows a wide range of hand motion and soft tissue preservation.

Key concepts: Intramedullary rod, Medicine, Fixation (population genetics), Metacarpal bones, Dash, Kirschner wire, Surgery, Range of motion

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative Study Between Intramedullary K Wires Versus Mini-plates and Screws in Fixation of Metacarpal Shaft Fractures in Adults — Research Paper | ScholarLens