Mitigation of CM conducted EMI in flyback converter using balancing capacitors
Ashritha Manjunath, M. L. Sudheer
Abstract
Ashritha Manjunath, M. L. Sudheer
Abstract
The offline Switched Mode Power Supply (SMPS) draw non‐sinusoidal line current from the utility power supply, thereby introducing unwanted harmonics and also generate significant electromagnetic interference (EMI). Power factor correction (PFC) converters can be used to improve the power factor. But they also generate EMI in both Differential Mode (DM) and Common Mode (CM). In this paper, the EMI generated by the flyback PFC converter is addressed. A lumped circuit model for CM conducted EMI generated in a flyback converter, including the HF transformer's parasitics and the components, is considered. The parasitics of the HF transformer are calculated and measured experimentally. Using them, the resonant frequencies of the flyback converter are calculated for validation. A technique for determining the required balancing capacitor to mitigate CM conducted EMI is presented. A novel technique by splitting this balancing capacitor with their mid‐point grounded for further reduction of this EMI is presented. This technique can eliminate the capacitors of the EMI line filter connected between line/neutral to the ground. Hence for the same amount of CM conducted EMI mitigation, the size and the cost of EMI line filters are reduced. Theoretical analysis, simulation results, and experimental verifications are presented.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The offline Switched Mode Power Supply (SMPS) draw non‐sinusoidal line current from the utility power supply, thereby introducing unwanted harmonics and also generate significant electromagnetic interference (EMI). Power factor correction (PFC) converters can be used to improve the power factor. But they also generate EMI in both Differential Mode (DM) and Common Mode (CM). In this paper, the EMI generated by the flyback PFC converter is addressed. A lumped circuit model for CM conducted EMI generated in a flyback converter, including the HF transformer's parasitics and the components, is considered. The parasitics of the HF transformer are calculated and measured experimentally. Using them, the resonant frequencies of the flyback converter are calculated for validation. A technique for determining the required balancing capacitor to mitigate CM conducted EMI is presented. A novel technique by splitting this balancing capacitor with their mid‐point grounded for further reduction of this EMI is presented. This technique can eliminate the capacitors of the EMI line filter connected between line/neutral to the ground. Hence for the same amount of CM conducted EMI mitigation, the size and the cost of EMI line filters are reduced. Theoretical analysis, simulation results, and experimental verifications are presented.
Key concepts: EMI, Electromagnetic interference, Electrical engineering, Flyback converter, Flyback transformer, Capacitor, Electronic engineering, Power factor