In vitro accuracies of 3D printed models manufactured by two different printing technologies
Faruk Emir, Gülsüm Ceylan, Simel Ayyıldız
Abstract
Faruk Emir, Gülsüm Ceylan, Simel Ayyıldız
Abstract
PURPOSE: This study aims to compare the accuracies of full-arch models printed by two different 3D printing technologies. MATERIALS AND METHODS: A mandibular horseshoe-shaped master model was designed with RapidForm XOR2 software The master model was printed 10 times with 3D printers using direct light processing (DLP) and PolyJet technology (n=20). The printed models were then scanned with an industrial scanner and saved in STL file. All digital models superimposed with the master model STL file and comparison of the trueness was performed using Geomagic Control 3D analysis software. The precision was calculated by superimposing combinations of the 10 data sets in each group. RESULTS: The trueness of printed models was 46 µm for the DLP printer and 51 µm for PolyJet printer; however, this difference was not statistically significant (p=0.155). The precision of printed models was 43 µm for the DLP printer and 54 µm for PolyJet printer. DLP printed models were more precise than the PolyJet printed models (p<0.001). CONCLUSION: The 3D printing technologies showed significant differences in the trueness of full-arch measurements. Although DLP printed models had better trueness than PolyJet printed models, all of the 3D printed models were clinically acceptable and might be used for the production of fixed restorations.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: This study aims to compare the accuracies of full-arch models printed by two different 3D printing technologies. MATERIALS AND METHODS: A mandibular horseshoe-shaped master model was designed with RapidForm XOR2 software The master model was printed 10 times with 3D printers using direct light processing (DLP) and PolyJet technology (n=20). The printed models were then scanned with an industrial scanner and saved in STL file. All digital models superimposed with the master model STL file and comparison of the trueness was performed using Geomagic Control 3D analysis software. The precision was calculated by superimposing combinations of the 10 data sets in each group. RESULTS: The trueness of printed models was 46 µm for the DLP printer and 51 µm for PolyJet printer; however, this difference was not statistically significant (p=0.155). The precision of printed models was 43 µm for the DLP printer and 54 µm for PolyJet printer. DLP printed models were more precise than the PolyJet printed models (p<0.001). CONCLUSION: The 3D printing technologies showed significant differences in the trueness of full-arch measurements. Although DLP printed models had better trueness than PolyJet printed models, all of the 3D printed models were clinically acceptable and might be used for the production of fixed restorations.
Key concepts: 3d printed, 3D printing, 3d printer, Digital printing, Digital Light Processing, Three dimensional printing, Software, 3d model