2019Repository hosted by TU Delft Library (TU Delft)Open access

Temperate Climate

Babak Raji, Martin Tenpierik, Andy van den Dobbelsteen

Open full text 0 citations

Abstract

The building envelope is the interface between the interior of the building and the outdoor environment. A building’s energy consumption to a large extent depends on certain envelope design elements. As a consequence, for achieving high levels of energysaving in buildings, design measures with high impact should be firstly defined and then optimised. This paper aims at finding energy-saving solutions for the envelope design of high-rise office buildings in temperate climates. For this purpose, an existing tall office building is selected as a typical high-rise design in the Netherlands and the energy use prior and after refurbishment is compared through computer simulations with DesignBuilder. A sensitivity analysis in line with a large number of energy performance simulations showed which building envelope parameters have a significant impact on the building’s energy consumption; hence need more consideration for improvement. The four measures selected for uplifting the energy performance of the building envelope include glazing type, window-to-wall ratio, sun shading and roof strategies. By taking the base case as a reference and optimising one parameter at each step, this study resulted in a high-performance envelope design that offers a considerable energy-saving by around 42% for total energy use, 64% for heating and 34% for electric lighting.

About this research paper

What this paper is about

The building envelope is the interface between the interior of the building and the outdoor environment. A building’s energy consumption to a large extent depends on certain envelope design elements. As a consequence, for achieving high levels of energysaving in buildings, design measures with high impact should be firstly defined and then optimised. This paper aims at finding energy-saving solutions for the envelope design of high-rise office buildings in temperate climates. For this purpose, an existing tall office building is selected as a typical high-rise design in the Netherlands and the energy use prior and after refurbishment is compared through computer simulations with DesignBuilder. A sensitivity analysis in line with a large number of energy performance simulations showed which building envelope parameters have a significant impact on the building’s energy consumption; hence need more consideration for improvement. The four measures selected for uplifting the energy performance of the building envelope include glazing type, window-to-wall ratio, sun shading and roof strategies. By taking the base case as a reference and optimising one parameter at each step, this study resulted in a high-performance envelope design that offers a considerable energy-saving by around 42% for total energy use, 64% for heating and 34% for electric lighting.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The building envelope is the interface between the interior of the building and the outdoor environment. A building’s energy consumption to a large extent depends on certain envelope design elements. As a consequence, for achieving high levels of energysaving in buildings, design measures with high impact should be firstly defined and then optimised. This paper aims at finding energy-saving solutions for the envelope design of high-rise office buildings in temperate climates. For this purpose, an existing tall office building is selected as a typical high-rise design in the Netherlands and the energy use prior and after refurbishment is compared through computer simulations with DesignBuilder. A sensitivity analysis in line with a large number of energy performance simulations showed which building envelope parameters have a significant impact on the building’s energy consumption; hence need more consideration for improvement. The four measures selected for uplifting the energy performance of the building envelope include glazing type, window-to-wall ratio, sun shading and roof strategies. By taking the base case as a reference and optimising one parameter at each step, this study resulted in a high-performance envelope design that offers a considerable energy-saving by around 42% for total energy use, 64% for heating and 34% for electric lighting.

Key concepts: Building envelope, Envelope (radar), Roof, Glazing, Energy consumption, Architectural engineering, Energy (signal processing), Efficient energy use