Temperate Climate
Babak Raji, Martin Tenpierik, Andy van den Dobbelsteen
Abstract
Babak Raji, Martin Tenpierik, Andy van den Dobbelsteen
Abstract
The building envelope is the interface between the interior of the building and the outdoor environment. A building’s energy consumption to a large extent depends on certain envelope design elements. As a consequence, for achieving high levels of energysaving in buildings, design measures with high impact should be firstly defined and then optimised. This paper aims at finding energy-saving solutions for the envelope design of high-rise office buildings in temperate climates. For this purpose, an existing tall office building is selected as a typical high-rise design in the Netherlands and the energy use prior and after refurbishment is compared through computer simulations with DesignBuilder. A sensitivity analysis in line with a large number of energy performance simulations showed which building envelope parameters have a significant impact on the building’s energy consumption; hence need more consideration for improvement. The four measures selected for uplifting the energy performance of the building envelope include glazing type, window-to-wall ratio, sun shading and roof strategies. By taking the base case as a reference and optimising one parameter at each step, this study resulted in a high-performance envelope design that offers a considerable energy-saving by around 42% for total energy use, 64% for heating and 34% for electric lighting.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The building envelope is the interface between the interior of the building and the outdoor environment. A building’s energy consumption to a large extent depends on certain envelope design elements. As a consequence, for achieving high levels of energysaving in buildings, design measures with high impact should be firstly defined and then optimised. This paper aims at finding energy-saving solutions for the envelope design of high-rise office buildings in temperate climates. For this purpose, an existing tall office building is selected as a typical high-rise design in the Netherlands and the energy use prior and after refurbishment is compared through computer simulations with DesignBuilder. A sensitivity analysis in line with a large number of energy performance simulations showed which building envelope parameters have a significant impact on the building’s energy consumption; hence need more consideration for improvement. The four measures selected for uplifting the energy performance of the building envelope include glazing type, window-to-wall ratio, sun shading and roof strategies. By taking the base case as a reference and optimising one parameter at each step, this study resulted in a high-performance envelope design that offers a considerable energy-saving by around 42% for total energy use, 64% for heating and 34% for electric lighting.
Key concepts: Building envelope, Envelope (radar), Roof, Glazing, Energy consumption, Architectural engineering, Energy (signal processing), Efficient energy use