2021Medical PhysicsOpen access

Does FLASH deplete oxygen? Experimental evaluation for photons, protons, and carbon ions

Jeannette Jansen, Jan Knoll, Elke Beyreuther, Jörg Pawelke, R. Skuza, Rachel Hanley, Stephan Brons, Francesca Pagliari, Joao Seco

Open full text 7 citations

Abstract

PURPOSE: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons, and carbon ions. METHODS: This study presents measurements of the oxygen consumption in sealed, 3D-printed water phantoms during irradiation with x-rays, protons, and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed using an optical sensor allowing for noninvasive measurements. RESULTS: Oxygen consumption in water only depends on dose, dose rate, and linear energy transfer (LET) of the irradiation. The total amount of oxygen depleted per 10 Gy was found to be 0.04% atm - 0.18% atm for 225 kV photons, 0.04% atm - 0.25% atm for 224 MeV protons, and 0.09% atm - 0.17% atm for carbon ions. Consumption depends on dose rate by an inverse power law and saturates for higher dose rates because of self-interactions of radicals. Higher dose rates yield lower oxygen consumption. No total depletion of oxygen was found for clinical doses. CONCLUSIONS: FLASH irradiation does consume oxygen, but not enough to deplete all the oxygen present. For higher dose rates, less oxygen was consumed than at standard radiotherapy dose rates. No total depletion was found for any of the analyzed radiation types for 10 Gy dose delivery using FLASH.

Open-access reader

About this research paper

What this paper is about

PURPOSE: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons, and carbon ions. METHODS: This study presents measurements of the oxygen consumption in sealed, 3D-printed water phantoms during irradiation with x-rays, protons, and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed using an optical sensor allowing for noninvasive measurements. RESULTS: Oxygen consumption in water only depends on dose, dose rate, and linear energy transfer (LET) of the irradiation. The total amount of oxygen depleted per 10 Gy was found to be 0.04% atm - 0.18% atm for 225 kV photons, 0.04% atm - 0.25% atm for 224 MeV protons, and 0.09% atm - 0.17% atm for carbon ions. Consumption depends on dose rate by an inverse power law and saturates for higher dose rates because of self-interactions of radicals. Higher dose rates yield lower oxygen consumption. No total depletion of oxygen was found for clinical doses. CONCLUSIONS: FLASH irradiation does consume oxygen, but not enough to deplete all the oxygen present. For higher dose rates, less oxygen was consumed than at standard radiotherapy dose rates. No total depletion was found for any of the analyzed radiation types for 10 Gy dose delivery using FLASH.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons, and carbon ions. METHODS: This study presents measurements of the oxygen consumption in sealed, 3D-printed water phantoms during irradiation with x-rays, protons, and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed using an optical sensor allowing for noninvasive measurements. RESULTS: Oxygen consumption in water only depends on dose, dose rate, and linear energy transfer (LET) of the irradiation. The total amount of oxygen depleted per 10 Gy was found to be 0.04% atm - 0.18% atm for 225 kV photons, 0.04% atm - 0.25% atm for 224 MeV protons, and 0.09% atm - 0.17% atm for carbon ions. Consumption depends on dose rate by an inverse power law and saturates for higher dose rates because of self-interactions of radicals. Higher dose rates yield lower oxygen consumption. No total depletion of oxygen was found for clinical doses. CONCLUSIONS: FLASH irradiation does consume oxygen, but not enough to deplete all the oxygen present. For higher dose rates, less oxygen was consumed than at standard radiotherapy dose rates. No total depletion was found for any of the analyzed radiation types for 10 Gy dose delivery using FLASH.

Key concepts: Oxygen, Irradiation, Flash (photography), Radiochemistry, Ion, Carbon fibers, Chemistry, Radiation

Related papers

Back to paper searchBrowse research topicsOriginal source
Does FLASH deplete oxygen? Experimental evaluation for photons, protons, and carbon ions — Research Paper | ScholarLens