2021IEEE Transactions on Neural Systems and Rehabilitation EngineeringOpen access

Detecting High Frequency Oscillations for Stereoelectroencephalography in Epilepsy via Hypergraph Learning

Jiayang Guo, Hailong Li, Xiaoshuai Sun, Lei Qi, Hui Qiao, Yijie Pan, Jing Xiang, Rongrong Ji

Open full text 18 citations

Abstract

Successful epilepsy surgeries depend highly on pre-operative localization of epileptogenic zones. Stereoelectroencephalography (SEEG) records interictal and ictal activities of the epilepsy in order to precisely find and localize epileptogenic zones in clinical practice. While it is difficult to find distinct ictal onset patterns generated the seizure onset zone from SEEG recordings in a confined region, high frequency oscillations are commonly considered as putative biomarkers for the identification of epileptogenic zones. Therefore, automatic and accurate detection of high frequency oscillations in SEEG signals is crucial for timely clinical evaluation. This work formulates the detection of high frequency oscillations as a signal segment classification problem and develops a hypergraph-based detector to automatically detect high frequency oscillations such that human experts can visually review SEEG signals. We evaluated our method on 4,000 signal segments from clinical SEEG recordings that contain both ictal and interictal data obtained from 19 patients who suffer from refractory focal epilepsy. The experimental results demonstrate the effectiveness of the proposed detector that can successfully localize interictal high frequency oscillations and outperforms multiple peer machine learning methods. In particular, the proposed detector achieved 90.7% in accuracy, 80.9% in sensitivity, and 96.9% in specificity.

Open-access reader

About this research paper

What this paper is about

Successful epilepsy surgeries depend highly on pre-operative localization of epileptogenic zones. Stereoelectroencephalography (SEEG) records interictal and ictal activities of the epilepsy in order to precisely find and localize epileptogenic zones in clinical practice. While it is difficult to find distinct ictal onset patterns generated the seizure onset zone from SEEG recordings in a confined region, high frequency oscillations are commonly considered as putative biomarkers for the identification of epileptogenic zones. Therefore, automatic and accurate detection of high frequency oscillations in SEEG signals is crucial for timely clinical evaluation. This work formulates the detection of high frequency oscillations as a signal segment classification problem and develops a hypergraph-based detector to automatically detect high frequency oscillations such that human experts can visually review SEEG signals. We evaluated our method on 4,000 signal segments from clinical SEEG recordings that contain both ictal and interictal data obtained from 19 patients who suffer from refractory focal epilepsy. The experimental results demonstrate the effectiveness of the proposed detector that can successfully localize interictal high frequency oscillations and outperforms multiple peer machine learning methods. In particular, the proposed detector achieved 90.7% in accuracy, 80.9% in sensitivity, and 96.9% in specificity.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Successful epilepsy surgeries depend highly on pre-operative localization of epileptogenic zones. Stereoelectroencephalography (SEEG) records interictal and ictal activities of the epilepsy in order to precisely find and localize epileptogenic zones in clinical practice. While it is difficult to find distinct ictal onset patterns generated the seizure onset zone from SEEG recordings in a confined region, high frequency oscillations are commonly considered as putative biomarkers for the identification of epileptogenic zones. Therefore, automatic and accurate detection of high frequency oscillations in SEEG signals is crucial for timely clinical evaluation. This work formulates the detection of high frequency oscillations as a signal segment classification problem and develops a hypergraph-based detector to automatically detect high frequency oscillations such that human experts can visually review SEEG signals. We evaluated our method on 4,000 signal segments from clinical SEEG recordings that contain both ictal and interictal data obtained from 19 patients who suffer from refractory focal epilepsy. The experimental results demonstrate the effectiveness of the proposed detector that can successfully localize interictal high frequency oscillations and outperforms multiple peer machine learning methods. In particular, the proposed detector achieved 90.7% in accuracy, 80.9% in sensitivity, and 96.9% in specificity.

Key concepts: Stereoelectroencephalography, Epilepsy, Neuroscience, Computer science, Psychology, Epilepsy surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Detecting High Frequency Oscillations for Stereoelectroencephalography in Epilepsy via Hypergraph Learning — Research Paper | ScholarLens