2021American Journal of AudiologyOpen access

Subclinical Auditory Dysfunction: Relationship Between Distortion Product Otoacoustic Emissions and the Audiogram

Naomi F. Bramhall, Garnett P. McMillan, Amy N. Mashburn

Open full text 12 citations

Abstract

Purpose Distortion product otoacoustic emissions (DPOAEs) and audiometric thresholds have been used to account for the impacts of subclinical outer hair cell (OHC) dysfunction on auditory perception and measures of auditory physiology. However, the relationship between DPOAEs and the audiogram is unclear. This study investigated this relationship by determining how well DPOAE levels can predict the audiogram among individuals with clinically normal hearing. Additionally, the impacts of age, noise exposure, and the perception of tinnitus on the ability of DPOAE levels to predict the audiogram were evaluated. Method Suprathreshold DPOAE levels from 1 to 10 kHz and pure-tone thresholds from 0.25 to 16 kHz were measured in 366 ears from 194 young adults (19–35 years old) with clinically normal audiograms and middle ear function. The measured DPOAE levels at all frequencies were used to predict pure-tone thresholds at each frequency. Participants were grouped by age, self-reported noise exposure/Veteran status, and self-report of tinnitus. Results Including DPOAE levels in the pure-tone threshold prediction model improved threshold predictions at all frequencies from 0.25 to 16 kHz compared with a model based only on sample mean pure-tone thresholds, but these improvements were modest. DPOAE levels for f 2 frequencies of 4 and 5 kHz were particularly influential in predicting pure-tone thresholds above 4 kHz. However, prediction accuracy varied based on participant characteristics. On average, predicted pure-tone thresholds were better than measured thresholds among Veterans, individuals with tinnitus, and the oldest age group. Conclusions These results indicate a complex relationship between DPOAE levels and the audiogram. Underestimation of pure-tone thresholds for some groups suggests that additional factors other than OHC damage may impact thresholds among individuals within these categories. These findings suggest that DPOAE levels and pure-tone thresholds may differ in terms of how well they reflect subclinical OHC dysfunction. Supplemental Material https://doi.org/10.23641/asha.13564745

Open-access reader

About this research paper

What this paper is about

Purpose Distortion product otoacoustic emissions (DPOAEs) and audiometric thresholds have been used to account for the impacts of subclinical outer hair cell (OHC) dysfunction on auditory perception and measures of auditory physiology. However, the relationship between DPOAEs and the audiogram is unclear. This study investigated this relationship by determining how well DPOAE levels can predict the audiogram among individuals with clinically normal hearing. Additionally, the impacts of age, noise exposure, and the perception of tinnitus on the ability of DPOAE levels to predict the audiogram were evaluated. Method Suprathreshold DPOAE levels from 1 to 10 kHz and pure-tone thresholds from 0.25 to 16 kHz were measured in 366 ears from 194 young adults (19–35 years old) with clinically normal audiograms and middle ear function. The measured DPOAE levels at all frequencies were used to predict pure-tone thresholds at each frequency. Participants were grouped by age, self-reported noise exposure/Veteran status, and self-report of tinnitus. Results Including DPOAE levels in the pure-tone threshold prediction model improved threshold predictions at all frequencies from 0.25 to 16 kHz compared with a model based only on sample mean pure-tone thresholds, but these improvements were modest. DPOAE levels for f 2 frequencies of 4 and 5 kHz were particularly influential in predicting pure-tone thresholds above 4 kHz. However, prediction accuracy varied based on participant characteristics. On average, predicted pure-tone thresholds were better than measured thresholds among Veterans, individuals with tinnitus, and the oldest age group. Conclusions These results indicate a complex relationship between DPOAE levels and the audiogram. Underestimation of pure-tone thresholds for some groups suggests that additional factors other than OHC damage may impact thresholds among individuals within these categories. These findings suggest that DPOAE levels and pure-tone thresholds may differ in terms of how well they reflect subclinical OHC dysfunction. Supplemental Material https://doi.org/10.23641/asha.13564745

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose Distortion product otoacoustic emissions (DPOAEs) and audiometric thresholds have been used to account for the impacts of subclinical outer hair cell (OHC) dysfunction on auditory perception and measures of auditory physiology. However, the relationship between DPOAEs and the audiogram is unclear. This study investigated this relationship by determining how well DPOAE levels can predict the audiogram among individuals with clinically normal hearing. Additionally, the impacts of age, noise exposure, and the perception of tinnitus on the ability of DPOAE levels to predict the audiogram were evaluated. Method Suprathreshold DPOAE levels from 1 to 10 kHz and pure-tone thresholds from 0.25 to 16 kHz were measured in 366 ears from 194 young adults (19–35 years old) with clinically normal audiograms and middle ear function. The measured DPOAE levels at all frequencies were used to predict pure-tone thresholds at each frequency. Participants were grouped by age, self-reported noise exposure/Veteran status, and self-report of tinnitus. Results Including DPOAE levels in the pure-tone threshold prediction model improved threshold predictions at all frequencies from 0.25 to 16 kHz compared with a model based only on sample mean pure-tone thresholds, but these improvements were modest. DPOAE levels for f 2 frequencies of 4 and 5 kHz were particularly influential in predicting pure-tone thresholds above 4 kHz. However, prediction accuracy varied based on participant characteristics. On average, predicted pure-tone thresholds were better than measured thresholds among Veterans, individuals with tinnitus, and the oldest age group. Conclusions These results indicate a complex relationship between DPOAE levels and the audiogram. Underestimation of pure-tone thresholds for some groups suggests that additional factors other than OHC damage may impact thresholds among individuals within these categories. These findings suggest that DPOAE levels and pure-tone thresholds may differ in terms of how well they reflect subclinical OHC dysfunction. Supplemental Material https://doi.org/10.23641/asha.13564745

Key concepts: Audiogram, Audiology, Tinnitus, Otoacoustic emission, Hearing loss, Medicine, Audiometry, Subclinical infection

Related papers

Back to paper searchBrowse research topicsOriginal source
Subclinical Auditory Dysfunction: Relationship Between Distortion Product Otoacoustic Emissions and the Audiogram — Research Paper | ScholarLens