Determination of crinamidine in dietary supplements by GC-MS/MS
Lien Le Thi, Anh Bạch Thúy, Khánh Cao Công, Hà Trần Nguyên, Hồng Hảo Lê Thị
Abstract
Open-access reader
Lien Le Thi, Anh Bạch Thúy, Khánh Cao Công, Hà Trần Nguyên, Hồng Hảo Lê Thị
Abstract
Open-access reader
The determination of crinamidine in dietary supplements content by mass spectrometry (GC-MS/MS) was developed and validated. The method was performed on the DB5MS column (30m x 0,25mm; 0,25 μm), in combination with the tandem mass spectrometry. The parameters of the method were evaluated for selectivity, calibration curve, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was highly linear (the coefficient of determination 0.9970) within the concentration range of 5ppm-50ppm. The recovery at three concentrations were above 90,1%. The limit of detection (LOD) and limit of quantification (LOQ) of the methods were 3 and 10 mg/kg, respectively. All obtained results were acceptable according to the AOAC for dietary supplements. The method was applied to analyze 34 samples in Hanoi.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The determination of crinamidine in dietary supplements content by mass spectrometry (GC-MS/MS) was developed and validated. The method was performed on the DB5MS column (30m x 0,25mm; 0,25 μm), in combination with the tandem mass spectrometry. The parameters of the method were evaluated for selectivity, calibration curve, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was highly linear (the coefficient of determination 0.9970) within the concentration range of 5ppm-50ppm. The recovery at three concentrations were above 90,1%. The limit of detection (LOD) and limit of quantification (LOQ) of the methods were 3 and 10 mg/kg, respectively. All obtained results were acceptable according to the AOAC for dietary supplements. The method was applied to analyze 34 samples in Hanoi.
Key concepts: Detection limit, Calibration curve, Chromatography, Chemistry, Mass spectrometry, Tandem mass spectrometry, Gas chromatography–mass spectrometry, Linear range