2019Indonesian Journal of Electrical Engineering and Computer ScienceOpen access

A passive islanding detection method for hybrid distributed generation system under balanced islanding

Ramireddy Chilakala, K. Suresh, P Anusha, Sk Najma, Bandari Rajkumar, B. Lakshmi

Open full text 14 citations

Abstract

To solve the energy consumption demand of the world and environmental problems in the future the distributed generation is considered an alternative approach. In this paper a new passive islanding detection technique was proposed for the Hybrid distributed generation (HDG) system based on changes in negative sequence voltage (NSV) and currents during an unintentional islanding. Islanding is caused in the distributed generation system due to failures in the power grid. As per distribution energy resources interconnection standards, it should be detected within 2 sec with the equipments connected to it. It is difficult to detect islanding during zero power imbalance condition. Sequence analyzer will separate the positive, negative and zero sequence components of voltages and currents from the voltages and currents obtained at the point of common coupling (PCC). During a wide range of power imbalance conditions the change in negative sequence voltage and currents are examined for islanding detection. The simulation shows that this method is free from Non detection zone, even at zero power imbalances between load and distribution generation. The computer simulations made in Matlab/ Simulink laboratory show the effectiveness of this method

Open-access reader

About this research paper

What this paper is about

To solve the energy consumption demand of the world and environmental problems in the future the distributed generation is considered an alternative approach. In this paper a new passive islanding detection technique was proposed for the Hybrid distributed generation (HDG) system based on changes in negative sequence voltage (NSV) and currents during an unintentional islanding. Islanding is caused in the distributed generation system due to failures in the power grid. As per distribution energy resources interconnection standards, it should be detected within 2 sec with the equipments connected to it. It is difficult to detect islanding during zero power imbalance condition. Sequence analyzer will separate the positive, negative and zero sequence components of voltages and currents from the voltages and currents obtained at the point of common coupling (PCC). During a wide range of power imbalance conditions the change in negative sequence voltage and currents are examined for islanding detection. The simulation shows that this method is free from Non detection zone, even at zero power imbalances between load and distribution generation. The computer simulations made in Matlab/ Simulink laboratory show the effectiveness of this method

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To solve the energy consumption demand of the world and environmental problems in the future the distributed generation is considered an alternative approach. In this paper a new passive islanding detection technique was proposed for the Hybrid distributed generation (HDG) system based on changes in negative sequence voltage (NSV) and currents during an unintentional islanding. Islanding is caused in the distributed generation system due to failures in the power grid. As per distribution energy resources interconnection standards, it should be detected within 2 sec with the equipments connected to it. It is difficult to detect islanding during zero power imbalance condition. Sequence analyzer will separate the positive, negative and zero sequence components of voltages and currents from the voltages and currents obtained at the point of common coupling (PCC). During a wide range of power imbalance conditions the change in negative sequence voltage and currents are examined for islanding detection. The simulation shows that this method is free from Non detection zone, even at zero power imbalances between load and distribution generation. The computer simulations made in Matlab/ Simulink laboratory show the effectiveness of this method

Key concepts: Islanding, Distributed generation, Voltage, Power (physics), Computer science, Spectrum analyzer, Interconnection, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A passive islanding detection method for hybrid distributed generation system under balanced islanding — Research Paper | ScholarLens