With the increase in oil prices, developing nations end up paying expensive electricity and heating bill. This leading study investigates the experimental development of a new energy-saving system by integrating a solar water heater and solar cooling absorption cycle with a conventional boiler for domestic hot water and heating purposes. The heating and cooling load calculations for space heating of the building were calculated using TRNSYS 14.1 computer software and the results were used in calculating the energy-saving value. A 65 flat plate solar collector-chiller system with a total surface area of 130 m2 was integrated with the boiler and used to supply heating and cooling for a three-story building (1500 m2) in Al Bayt University, Jordan. The integrated system helped to save energy, reduced the emission of CO2 into the atmosphere, supplied hot water, and space heating/cooling requirements to the building year-round, and reduced the overall energy cost of heating and cooling by 55% and 48%, respectively. Moreover, the techno-economic analysis showed that the payback period of the combined system with a total cost of $18,650 is roughly 2.5-year. The solar water heating/cooling system has the potential to provide more than 50% of the house energy demand free of charge with a significant reduction in carbon footprint.

Open-access reader

About this research paper

What this paper is about

With the increase in oil prices, developing nations end up paying expensive electricity and heating bill. This leading study investigates the experimental development of a new energy-saving system by integrating a solar water heater and solar cooling absorption cycle with a conventional boiler for domestic hot water and heating purposes. The heating and cooling load calculations for space heating of the building were calculated using TRNSYS 14.1 computer software and the results were used in calculating the energy-saving value. A 65 flat plate solar collector-chiller system with a total surface area of 130 m2 was integrated with the boiler and used to supply heating and cooling for a three-story building (1500 m2) in Al Bayt University, Jordan. The integrated system helped to save energy, reduced the emission of CO2 into the atmosphere, supplied hot water, and space heating/cooling requirements to the building year-round, and reduced the overall energy cost of heating and cooling by 55% and 48%, respectively. Moreover, the techno-economic analysis showed that the payback period of the combined system with a total cost of $18,650 is roughly 2.5-year. The solar water heating/cooling system has the potential to provide more than 50% of the house energy demand free of charge with a significant reduction in carbon footprint.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With the increase in oil prices, developing nations end up paying expensive electricity and heating bill. This leading study investigates the experimental development of a new energy-saving system by integrating a solar water heater and solar cooling absorption cycle with a conventional boiler for domestic hot water and heating purposes. The heating and cooling load calculations for space heating of the building were calculated using TRNSYS 14.1 computer software and the results were used in calculating the energy-saving value. A 65 flat plate solar collector-chiller system with a total surface area of 130 m2 was integrated with the boiler and used to supply heating and cooling for a three-story building (1500 m2) in Al Bayt University, Jordan. The integrated system helped to save energy, reduced the emission of CO2 into the atmosphere, supplied hot water, and space heating/cooling requirements to the building year-round, and reduced the overall energy cost of heating and cooling by 55% and 48%, respectively. Moreover, the techno-economic analysis showed that the payback period of the combined system with a total cost of $18,650 is roughly 2.5-year. The solar water heating/cooling system has the potential to provide more than 50% of the house energy demand free of charge with a significant reduction in carbon footprint.

Key concepts: TRNSYS, Payback period, Boiler (water heating), Solar water heating, Solar air conditioning, Solar energy, Chiller, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Techno-Economic Investigation of an Integrated Boiler–Solar Water Heating/Cooling System: A Case Study — Research Paper | ScholarLens