2020•International Journal of Chemical Reactor EngineeringRequires access

Effect of H/D ratio and impeller type on power consumption of agitator in continuous stirred tank reactor for nitrocellulose production from cotton linter and nitric acid

Marcelinus Christwardana, Gregorius Rionugroho Harvianto, Kudrat Sunandar, Willy Dwi Novian, Rafi Ramanto

Open publisher page 2 citations

Abstract

Abstract In this study, the effect of height/diameter (H/D) ratio and type of impeller on the power consumption of the agitator in the Continuous Stirred Tank Reactor (CSTR) was analyzed. CSTR in the process of producing nitrocellulose from cotton linters with a production capacity of 10,000 tons/year was used as a case study. In designing a CSTR, power consumption is also considered because it is related to techno-economics. The results show that it is necessary to adjust the amount of impeller related to the H/D ratio value because it can affect the level of liquid in the reactor during the stirring process so that it also affects the reaction conversion. This work shows that with the higher H/D ratio, the greater number of impellers needed and increase the agitator power consumption. For specific applications, the number of impellers (NT) must be increased to meet the minimum power consumption. As the result, this work recommends the optimal H/D ratio for CSTR design is the maximum H/D ratio to get the NT-calculation as close as to the NT-taken while satisfying the minimum power consumption required. The optimal H/D ratio can be different depending on the impeller type and application.

About this research paper

What this paper is about

Abstract In this study, the effect of height/diameter (H/D) ratio and type of impeller on the power consumption of the agitator in the Continuous Stirred Tank Reactor (CSTR) was analyzed. CSTR in the process of producing nitrocellulose from cotton linters with a production capacity of 10,000 tons/year was used as a case study. In designing a CSTR, power consumption is also considered because it is related to techno-economics. The results show that it is necessary to adjust the amount of impeller related to the H/D ratio value because it can affect the level of liquid in the reactor during the stirring process so that it also affects the reaction conversion. This work shows that with the higher H/D ratio, the greater number of impellers needed and increase the agitator power consumption. For specific applications, the number of impellers (NT) must be increased to meet the minimum power consumption. As the result, this work recommends the optimal H/D ratio for CSTR design is the maximum H/D ratio to get the NT-calculation as close as to the NT-taken while satisfying the minimum power consumption required. The optimal H/D ratio can be different depending on the impeller type and application.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract In this study, the effect of height/diameter (H/D) ratio and type of impeller on the power consumption of the agitator in the Continuous Stirred Tank Reactor (CSTR) was analyzed. CSTR in the process of producing nitrocellulose from cotton linters with a production capacity of 10,000 tons/year was used as a case study. In designing a CSTR, power consumption is also considered because it is related to techno-economics. The results show that it is necessary to adjust the amount of impeller related to the H/D ratio value because it can affect the level of liquid in the reactor during the stirring process so that it also affects the reaction conversion. This work shows that with the higher H/D ratio, the greater number of impellers needed and increase the agitator power consumption. For specific applications, the number of impellers (NT) must be increased to meet the minimum power consumption. As the result, this work recommends the optimal H/D ratio for CSTR design is the maximum H/D ratio to get the NT-calculation as close as to the NT-taken while satisfying the minimum power consumption required. The optimal H/D ratio can be different depending on the impeller type and application.

Key concepts: Agitator, Continuous stirred-tank reactor, Impeller, Power consumption, Power (physics), Chemistry, Process engineering, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of H/D ratio and impeller type on power consumption of agitator in continuous stirred tank reactor for nitrocellulose production from cotton linter and nitric acid — Research Paper | ScholarLens