2020DOAJ (DOAJ: Directory of Open Access Journals)Open access

Determination of Ascorbic Acid Content using the Reverse Phase–High Performance Liquid Chromatography (RP-HPLC) Method

Nurul Ismillayli, Dhony Hermanto, I. G. A. Sri Andayani, Ruru Honiar, Ulul Khairi Zuryati, Baiq Mariana, Linda Marta Shofiyana

Open full text 2 citations

Abstract

A method of reverse phase-high performance liquid chromatography (RP-HPLC) was evaluated in ascorbic acid determination. The determination was conducted at optimum conditions for RP-HPLC method, including ethanol as mobile phase, flow velocity of 0.8 mL/min, running time of 5 minutes, injection volume of 10 µL, UV detector, wavelength of 245 nm with internal standard of ascorbic acid in metaphosphate-acetic acid. Result of measurement was validated by AOAC Official Method 967.21. It was obtained that RP-HPLC method was high sensitive and precision method due to its limit of detection was 0,5 µg/mL and RSD was ≤ 2%. The results of the determination of vitamin C content in fresh ceruring fruit using RP-HPLC method and the titrimetry method namely, 52.9057 ± 0.17 and 54.2066 ± 0.87 mg in 100 g sample, respectively. Based on statistical analysis (t-test), there were no significant differences for the two methods used. The percentage of recovery obtained is excellent in the range of 97.9-104.3%. Therefore, the RP-HPLC method is expected to be an accurate method for routine analysis of vitamin C. Key word: ascorbic acid, reverse phase, HPLC, titrimetric.

About this research paper

What this paper is about

A method of reverse phase-high performance liquid chromatography (RP-HPLC) was evaluated in ascorbic acid determination. The determination was conducted at optimum conditions for RP-HPLC method, including ethanol as mobile phase, flow velocity of 0.8 mL/min, running time of 5 minutes, injection volume of 10 µL, UV detector, wavelength of 245 nm with internal standard of ascorbic acid in metaphosphate-acetic acid. Result of measurement was validated by AOAC Official Method 967.21. It was obtained that RP-HPLC method was high sensitive and precision method due to its limit of detection was 0,5 µg/mL and RSD was ≤ 2%. The results of the determination of vitamin C content in fresh ceruring fruit using RP-HPLC method and the titrimetry method namely, 52.9057 ± 0.17 and 54.2066 ± 0.87 mg in 100 g sample, respectively. Based on statistical analysis (t-test), there were no significant differences for the two methods used. The percentage of recovery obtained is excellent in the range of 97.9-104.3%. Therefore, the RP-HPLC method is expected to be an accurate method for routine analysis of vitamin C. Key word: ascorbic acid, reverse phase, HPLC, titrimetric.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method of reverse phase-high performance liquid chromatography (RP-HPLC) was evaluated in ascorbic acid determination. The determination was conducted at optimum conditions for RP-HPLC method, including ethanol as mobile phase, flow velocity of 0.8 mL/min, running time of 5 minutes, injection volume of 10 µL, UV detector, wavelength of 245 nm with internal standard of ascorbic acid in metaphosphate-acetic acid. Result of measurement was validated by AOAC Official Method 967.21. It was obtained that RP-HPLC method was high sensitive and precision method due to its limit of detection was 0,5 µg/mL and RSD was ≤ 2%. The results of the determination of vitamin C content in fresh ceruring fruit using RP-HPLC method and the titrimetry method namely, 52.9057 ± 0.17 and 54.2066 ± 0.87 mg in 100 g sample, respectively. Based on statistical analysis (t-test), there were no significant differences for the two methods used. The percentage of recovery obtained is excellent in the range of 97.9-104.3%. Therefore, the RP-HPLC method is expected to be an accurate method for routine analysis of vitamin C. Key word: ascorbic acid, reverse phase, HPLC, titrimetric.

Key concepts: Ascorbic acid, High-performance liquid chromatography, Chromatography, Chemistry, Titration, Dehydroascorbic acid, Acetic acid, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Ascorbic Acid Content using the Reverse Phase–High Performance Liquid Chromatography (RP-HPLC) Method — Research Paper | ScholarLens