BACKGROUND: This study aimed to evaluate the efficacy of hemi-epiphysiodesis using a new device (X-plate) for the correction of genu valgum. METHODS: In total, 22 children with a total of 34 pathologic knee valgus deformities underwent the procedure and were followed up 25.3 months on average. RESULTS: The mean time to clinical correction of genu valgum was 10.9±2.2 months. Furthermore, the mean preoperative anatomic Lateral Distal Femoral Angle (aLDFA) and mechanical Tibia Femoral angle (mTFA) were obtained at 75.1±3.8 and 6±2.8 degrees, respectively. When clinical correction of the deformity was achieved, the mean of aLDFA and mTFA corrections were determined at 8.9±5.3 and 6.5±3.2 degrees, respectively. The mean speed of aLDFA and mTFA corrections were estimated at 0.8±0.45 and 0.6±0.3 degrees per month, respectively. The postoperative aLDFA and mTFA were measured at 84±4.2 and -0.8±2.9 on average. With a mean of 25.3±14.5 months at final follow-up, there were 6 (17.6%) mild valgus knees, 26 (75.5%) normal alignment knees, and only 2 (5.9%) mild varus knee within an acceptable clinical limit. CONCLUSION: Hemi-epiphysiodesis using X-plate at the distal physis of the femur is an effective and safe method for the treatment of valgus knee deformity in children.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: This study aimed to evaluate the efficacy of hemi-epiphysiodesis using a new device (X-plate) for the correction of genu valgum. METHODS: In total, 22 children with a total of 34 pathologic knee valgus deformities underwent the procedure and were followed up 25.3 months on average. RESULTS: The mean time to clinical correction of genu valgum was 10.9±2.2 months. Furthermore, the mean preoperative anatomic Lateral Distal Femoral Angle (aLDFA) and mechanical Tibia Femoral angle (mTFA) were obtained at 75.1±3.8 and 6±2.8 degrees, respectively. When clinical correction of the deformity was achieved, the mean of aLDFA and mTFA corrections were determined at 8.9±5.3 and 6.5±3.2 degrees, respectively. The mean speed of aLDFA and mTFA corrections were estimated at 0.8±0.45 and 0.6±0.3 degrees per month, respectively. The postoperative aLDFA and mTFA were measured at 84±4.2 and -0.8±2.9 on average. With a mean of 25.3±14.5 months at final follow-up, there were 6 (17.6%) mild valgus knees, 26 (75.5%) normal alignment knees, and only 2 (5.9%) mild varus knee within an acceptable clinical limit. CONCLUSION: Hemi-epiphysiodesis using X-plate at the distal physis of the femur is an effective and safe method for the treatment of valgus knee deformity in children.
Key concepts: Epiphysiodesis, Genu Valgum, Medicine, Valgus deformity, Valgus, Genu varum, Deformity, Femur