2020Nuclear FusionOpen access

New assessment of the fast ion energy in ASDEX upgrade H-mode discharges

G. Tardini, M. Weiland, C. Angioni, M. Cavedon, Francois Ryter, Philip A. Schneider, the ASDEX Upgrade Team

Open full text 10 citations

Abstract

Abstract Confinement scaling laws such as IPB98(y, 2) are widely used to extrapolate the performance of present tokamaks to next-step devices such as ITER or DEMO. The thermal energy of the plasma (W th), which is used to determine the energy confinement time for most scaling laws, is difficult to measure, due to the sizeable uncertainties in the experimental kinetic profiles. The common approach in the tokamak community is to derive W th as the difference between the measured magnetohydrodynamic (MHD) energy and some simulation-based estimate of the fast ion energy W fi. In H-mode plasmas W fi can be as high as W th, in presence of neutral beam injection (NBI) or ion cyclotron radio frequency heating (ICRF), therefore an accurate assessment of W fi is crucial to have a somewhat reliable H-factor, regardless of the power-scaling of a given scaling law. In this paper we aim at evaluating the current approach to estimate W fi, by comparing its predictions with a wide database of calculations using validated NBI codes. Systematic deviations and trends, as well as statistical scatter are discussed. We use a comprehensive database of AUG H-mode deuterium plasmas, with significant variations of plasma current, NBI power and plasma density. We neglect thereby the fast-ion losses caused by MHD modes and the synergy effect between NBI and ICRF. A new approach is proposed based on the newly developed fast NBI code RABBIT.

Open-access reader

About this research paper

What this paper is about

Abstract Confinement scaling laws such as IPB98(y, 2) are widely used to extrapolate the performance of present tokamaks to next-step devices such as ITER or DEMO. The thermal energy of the plasma (W th), which is used to determine the energy confinement time for most scaling laws, is difficult to measure, due to the sizeable uncertainties in the experimental kinetic profiles. The common approach in the tokamak community is to derive W th as the difference between the measured magnetohydrodynamic (MHD) energy and some simulation-based estimate of the fast ion energy W fi. In H-mode plasmas W fi can be as high as W th, in presence of neutral beam injection (NBI) or ion cyclotron radio frequency heating (ICRF), therefore an accurate assessment of W fi is crucial to have a somewhat reliable H-factor, regardless of the power-scaling of a given scaling law. In this paper we aim at evaluating the current approach to estimate W fi, by comparing its predictions with a wide database of calculations using validated NBI codes. Systematic deviations and trends, as well as statistical scatter are discussed. We use a comprehensive database of AUG H-mode deuterium plasmas, with significant variations of plasma current, NBI power and plasma density. We neglect thereby the fast-ion losses caused by MHD modes and the synergy effect between NBI and ICRF. A new approach is proposed based on the newly developed fast NBI code RABBIT.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Confinement scaling laws such as IPB98(y, 2) are widely used to extrapolate the performance of present tokamaks to next-step devices such as ITER or DEMO. The thermal energy of the plasma (W th), which is used to determine the energy confinement time for most scaling laws, is difficult to measure, due to the sizeable uncertainties in the experimental kinetic profiles. The common approach in the tokamak community is to derive W th as the difference between the measured magnetohydrodynamic (MHD) energy and some simulation-based estimate of the fast ion energy W fi. In H-mode plasmas W fi can be as high as W th, in presence of neutral beam injection (NBI) or ion cyclotron radio frequency heating (ICRF), therefore an accurate assessment of W fi is crucial to have a somewhat reliable H-factor, regardless of the power-scaling of a given scaling law. In this paper we aim at evaluating the current approach to estimate W fi, by comparing its predictions with a wide database of calculations using validated NBI codes. Systematic deviations and trends, as well as statistical scatter are discussed. We use a comprehensive database of AUG H-mode deuterium plasmas, with significant variations of plasma current, NBI power and plasma density. We neglect thereby the fast-ion losses caused by MHD modes and the synergy effect between NBI and ICRF. A new approach is proposed based on the newly developed fast NBI code RABBIT.

Key concepts: ASDEX Upgrade, Tokamak, Plasma, Divertor, Physics, Magnetohydrodynamics, Scaling, Computational physics

Related papers

Back to paper searchBrowse research topicsOriginal source
New assessment of the fast ion energy in ASDEX upgrade H-mode discharges — Research Paper | ScholarLens