2013•Acta Physica SinicaOpen access

Study of inhomogeneous tissue equivalent water thickness correction method in proton therapy

Zhao Xie, Zou Lian, Hou Qing, Zheng Xia

Open full text 2 citations

Abstract

The inhomogeneous tissue equivalent water thickness correction method is an important part of research in proton radiotherapy. In this paper, we simulate the transport processes of a high-energy proton beam being injected into the water and other materials using Monte-Carlo multi-particle transport code Fluka, and according to the energy deposition distribution we obtain the depth of the Bragg peak when the protons are injected into different materials. Then we fit an analytic formula (R = αE0p) to the relationship between initial proton energy and the depth of the proton Bragg peak in different materials. It is found that for the different energies of proton beam being injected into non-uniform organization, the difference between the Bragg peak depth from fitting and the depth of the proton beam Bragg peaks from Fluka program is less than 1 mm. If we can establish a database about the relationship of Bragg peak ratio between medium and water, with electron density, then the equivalent water thickness correction method will be able to applied to the dose calculation of for homogeneous medium in proton therapy.

About this research paper

What this paper is about

The inhomogeneous tissue equivalent water thickness correction method is an important part of research in proton radiotherapy. In this paper, we simulate the transport processes of a high-energy proton beam being injected into the water and other materials using Monte-Carlo multi-particle transport code Fluka, and according to the energy deposition distribution we obtain the depth of the Bragg peak when the protons are injected into different materials. Then we fit an analytic formula (R = αE0p) to the relationship between initial proton energy and the depth of the proton Bragg peak in different materials. It is found that for the different energies of proton beam being injected into non-uniform organization, the difference between the Bragg peak depth from fitting and the depth of the proton beam Bragg peaks from Fluka program is less than 1 mm. If we can establish a database about the relationship of Bragg peak ratio between medium and water, with electron density, then the equivalent water thickness correction method will be able to applied to the dose calculation of for homogeneous medium in proton therapy.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The inhomogeneous tissue equivalent water thickness correction method is an important part of research in proton radiotherapy. In this paper, we simulate the transport processes of a high-energy proton beam being injected into the water and other materials using Monte-Carlo multi-particle transport code Fluka, and according to the energy deposition distribution we obtain the depth of the Bragg peak when the protons are injected into different materials. Then we fit an analytic formula (R = αE0p) to the relationship between initial proton energy and the depth of the proton Bragg peak in different materials. It is found that for the different energies of proton beam being injected into non-uniform organization, the difference between the Bragg peak depth from fitting and the depth of the proton beam Bragg peaks from Fluka program is less than 1 mm. If we can establish a database about the relationship of Bragg peak ratio between medium and water, with electron density, then the equivalent water thickness correction method will be able to applied to the dose calculation of for homogeneous medium in proton therapy.

Key concepts: Bragg peak, Proton, Proton therapy, Beam (structure), Monte Carlo method, Materials science, Particle therapy, Energy (signal processing)