2014•Unpublished venueRequires access

Tunnelling on Northern Beaches Storage Project, Sydney, to improve water quality

Nerida Taylor, PB Hewitt

Open publisher page 0 citations

Abstract

The Northern Beaches Storage Project (NBSP) is part of Sydney Water's SewerFix Program to improve the wastewater system and protect public health and the environment. It was built by the SewerFix Wet Weather Alliance (the Alliance), a partnership between Sydney Water, RPS, MWH, Parsons Brinckerhoff and United Group Infrastructure. The project temporarily stores excess wastewater diverted from the Narrabeen Submain during wet weather. The project considered a below-ground storage facility, which involved constructing a deep tunnel from Brookvale to Fairlight, connecting into the Northside Storage Tunnel and a storage tank, which was subsequently adopted and constructed. The storage tank scheme included a pumping station and inlet and outlet pipes installed by microtunnelling. The storage tank site is in the Brookvale industrial area situated in an area of deep marine sediments overlying Hawkesbury Sandstone at about 30 m below ground. Microtunnelling for the inlet pipe was conducted from a 12 m deep jacking shaft. The jacking shaft and 14 m deep pumping station excavations were carried out from within secant pile earth retaining structures adjacent to existing buildings. Construction activities had the potential to cause settlement of the adjacent buildings. During excavation and microtunnelling the water ingress, adjacent groundwater level and settlement of the adjacent buildings were monitored. The monitoring data was assessed against an action plan, which modified construction activities as required to minimise the risk of damage to buildings from settlements caused by lowering of the groundwater table outside the excavations. The secant pile construction, excavation, microtunnelling and pumping station construction proceeded without incident or damage to adjacent buildings. This paper highlights that tunnel/underground options should be considered during options development, describes the original storage tunnel scheme and presents details of the successful microtunnelling and deep shaft construction adopted on the NBSP.

About this research paper

What this paper is about

The Northern Beaches Storage Project (NBSP) is part of Sydney Water's SewerFix Program to improve the wastewater system and protect public health and the environment. It was built by the SewerFix Wet Weather Alliance (the Alliance), a partnership between Sydney Water, RPS, MWH, Parsons Brinckerhoff and United Group Infrastructure. The project temporarily stores excess wastewater diverted from the Narrabeen Submain during wet weather. The project considered a below-ground storage facility, which involved constructing a deep tunnel from Brookvale to Fairlight, connecting into the Northside Storage Tunnel and a storage tank, which was subsequently adopted and constructed. The storage tank scheme included a pumping station and inlet and outlet pipes installed by microtunnelling. The storage tank site is in the Brookvale industrial area situated in an area of deep marine sediments overlying Hawkesbury Sandstone at about 30 m below ground. Microtunnelling for the inlet pipe was conducted from a 12 m deep jacking shaft. The jacking shaft and 14 m deep pumping station excavations were carried out from within secant pile earth retaining structures adjacent to existing buildings. Construction activities had the potential to cause settlement of the adjacent buildings. During excavation and microtunnelling the water ingress, adjacent groundwater level and settlement of the adjacent buildings were monitored. The monitoring data was assessed against an action plan, which modified construction activities as required to minimise the risk of damage to buildings from settlements caused by lowering of the groundwater table outside the excavations. The secant pile construction, excavation, microtunnelling and pumping station construction proceeded without incident or damage to adjacent buildings. This paper highlights that tunnel/underground options should be considered during options development, describes the original storage tunnel scheme and presents details of the successful microtunnelling and deep shaft construction adopted on the NBSP.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Northern Beaches Storage Project (NBSP) is part of Sydney Water's SewerFix Program to improve the wastewater system and protect public health and the environment. It was built by the SewerFix Wet Weather Alliance (the Alliance), a partnership between Sydney Water, RPS, MWH, Parsons Brinckerhoff and United Group Infrastructure. The project temporarily stores excess wastewater diverted from the Narrabeen Submain during wet weather. The project considered a below-ground storage facility, which involved constructing a deep tunnel from Brookvale to Fairlight, connecting into the Northside Storage Tunnel and a storage tank, which was subsequently adopted and constructed. The storage tank scheme included a pumping station and inlet and outlet pipes installed by microtunnelling. The storage tank site is in the Brookvale industrial area situated in an area of deep marine sediments overlying Hawkesbury Sandstone at about 30 m below ground. Microtunnelling for the inlet pipe was conducted from a 12 m deep jacking shaft. The jacking shaft and 14 m deep pumping station excavations were carried out from within secant pile earth retaining structures adjacent to existing buildings. Construction activities had the potential to cause settlement of the adjacent buildings. During excavation and microtunnelling the water ingress, adjacent groundwater level and settlement of the adjacent buildings were monitored. The monitoring data was assessed against an action plan, which modified construction activities as required to minimise the risk of damage to buildings from settlements caused by lowering of the groundwater table outside the excavations. The secant pile construction, excavation, microtunnelling and pumping station construction proceeded without incident or damage to adjacent buildings. This paper highlights that tunnel/underground options should be considered during options development, describes the original storage tunnel scheme and presents details of the successful microtunnelling and deep shaft construction adopted on the NBSP.

Key concepts: Jacking, Excavation, Pile, Settlement (finance), Water storage, Groundwater, Dredging, Human settlement

Related papers

Back to paper searchBrowse research topicsOriginal source
Tunnelling on Northern Beaches Storage Project, Sydney, to improve water quality — Research Paper | ScholarLens