2020Ground WaterRequires access

Flowing Well—Time‐Domain Solution and Inverse Problem Revisited

Tomas Perina

Open publisher page 10 citations

Abstract

Time-domain analytical solution for groundwater flow to a fully penetrating flowing well is derived using the same substitution technique used to re-derive (Perina 2010) the Theis (1935) equation and the approximate solution by Mishra and Guyonnet (1992) is confirmed. The exponential integral-based flowing well function is a computationally effective alternative to the original Jacob and Lohman (1952) solution in integral form. For a constant drawdown test, the ratio of drawdown at an observation well to the flowrate is equivalent to drawdown response to pumping at unit constant rate; the transformed observations can be analyzed using the Theis (1935) function. Analysis of field test shows that simultaneous fitting to measurements of flow from the test well and drawdown at an observation well results in more accurate and better resolved estimates of aquifer properties than fitting to flow observations only.

About this research paper

What this paper is about

Time-domain analytical solution for groundwater flow to a fully penetrating flowing well is derived using the same substitution technique used to re-derive (Perina 2010) the Theis (1935) equation and the approximate solution by Mishra and Guyonnet (1992) is confirmed. The exponential integral-based flowing well function is a computationally effective alternative to the original Jacob and Lohman (1952) solution in integral form. For a constant drawdown test, the ratio of drawdown at an observation well to the flowrate is equivalent to drawdown response to pumping at unit constant rate; the transformed observations can be analyzed using the Theis (1935) function. Analysis of field test shows that simultaneous fitting to measurements of flow from the test well and drawdown at an observation well results in more accurate and better resolved estimates of aquifer properties than fitting to flow observations only.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Time-domain analytical solution for groundwater flow to a fully penetrating flowing well is derived using the same substitution technique used to re-derive (Perina 2010) the Theis (1935) equation and the approximate solution by Mishra and Guyonnet (1992) is confirmed. The exponential integral-based flowing well function is a computationally effective alternative to the original Jacob and Lohman (1952) solution in integral form. For a constant drawdown test, the ratio of drawdown at an observation well to the flowrate is equivalent to drawdown response to pumping at unit constant rate; the transformed observations can be analyzed using the Theis (1935) function. Analysis of field test shows that simultaneous fitting to measurements of flow from the test well and drawdown at an observation well results in more accurate and better resolved estimates of aquifer properties than fitting to flow observations only.

Key concepts: Drawdown (hydrology), Aquifer test, Exponential function, Aquifer, Constant (computer programming), Well test (oil and gas), Flow (mathematics), Groundwater flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Flowing Well—Time‐Domain Solution and Inverse Problem Revisited — Research Paper | ScholarLens