Membrane-Based Portable Colorimetric Gaseous Chlorine Sensing Probe
Ming Tao Zhou, Tianling Li, Chao Xing, Yang Liu, Huijun Zhao
Abstract
Ming Tao Zhou, Tianling Li, Chao Xing, Yang Liu, Huijun Zhao
Abstract
Highly toxic chlorine gas imposes serious health risks in the workplace. The ability to on-site, real-time monitoring of instantaneous and time-weighted average (TWA) chlorine gas concentrations in a simple, sensitive, accurate, and reliable manner would be highly beneficial to improve workplace health and safety. Here, we propose and experimentally validate a gaseous chlorine detection principle based on a N, N -diethyl- p -phenylenediamine sulfate salt/Cl 2 colorimetric reaction-controlled membrane process to regulate the gaseous chlorine transport across a gas-permeable membrane that enables the establishment of a time-resolved analytical relationship to quantify chlorine concentration by multidata points with dramatically enhanced accuracy and reliability. A gas-permeable membrane-based portable colorimetric gaseous chlorine sensing probe (MCSP) was designed and fabricated. The MCSP embedded the proposed analytical principle that is capable of real-time continuous monitoring of the instantaneous and TWA chlorine gas concentrations within an analytical range of 0.009–2.058 mg L –1 without the need for on-going calibration, which could be a useful analytical tool for managing the toxic chlorine gas-imposed health risks in workplaces.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Highly toxic chlorine gas imposes serious health risks in the workplace. The ability to on-site, real-time monitoring of instantaneous and time-weighted average (TWA) chlorine gas concentrations in a simple, sensitive, accurate, and reliable manner would be highly beneficial to improve workplace health and safety. Here, we propose and experimentally validate a gaseous chlorine detection principle based on a N, N -diethyl- p -phenylenediamine sulfate salt/Cl 2 colorimetric reaction-controlled membrane process to regulate the gaseous chlorine transport across a gas-permeable membrane that enables the establishment of a time-resolved analytical relationship to quantify chlorine concentration by multidata points with dramatically enhanced accuracy and reliability. A gas-permeable membrane-based portable colorimetric gaseous chlorine sensing probe (MCSP) was designed and fabricated. The MCSP embedded the proposed analytical principle that is capable of real-time continuous monitoring of the instantaneous and TWA chlorine gas concentrations within an analytical range of 0.009–2.058 mg L –1 without the need for on-going calibration, which could be a useful analytical tool for managing the toxic chlorine gas-imposed health risks in workplaces.
Key concepts: Chlorine, Chemistry, Chlorine gas, Membrane, Calibration, Environmental chemistry, Inorganic chemistry, Analytical Chemistry (journal)