2009•Yaowu fenxi zazhiRequires access

HPLC simultaneous determination of schizandrin,imperatorin and osthole in Qirong tablets

Zhao Huai-qing

Open publisher page 0 citations

Abstract

Objective:To develop an HPLC method for simultaneous determination of schizandrin,imperatorin and osthole in Qirong tablets.Methods:The analysis was performed on a Diamonsil C18 column(200 mm×4.6 mm,5 μm) with a mobile phase of methanol-water(65∶35).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃. The detection wavelength was set at 250 nm.Results:The calibration curve was linear within the range of 4-40 μg·mL-1(r=0.9997) for schizandrin,2.46-24.6 μg·mL-1(r=0.9999) for imperatorin,and 16.5-165 μg·mL-1(r=0.9997) for osthole,respectively;The recoveries(n=9) of schizandrin,imperatorin and osthole were 102.3%,101.5%,and 102.0%,respectively. Conclusion:The method is simple,accurate and selective. It can be applied to determine schizandrin,imperatorin and osthole in Qirong tablets.

About this research paper

What this paper is about

Objective:To develop an HPLC method for simultaneous determination of schizandrin,imperatorin and osthole in Qirong tablets.Methods:The analysis was performed on a Diamonsil C18 column(200 mm×4.6 mm,5 μm) with a mobile phase of methanol-water(65∶35).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃. The detection wavelength was set at 250 nm.Results:The calibration curve was linear within the range of 4-40 μg·mL-1(r=0.9997) for schizandrin,2.46-24.6 μg·mL-1(r=0.9999) for imperatorin,and 16.5-165 μg·mL-1(r=0.9997) for osthole,respectively;The recoveries(n=9) of schizandrin,imperatorin and osthole were 102.3%,101.5%,and 102.0%,respectively. Conclusion:The method is simple,accurate and selective. It can be applied to determine schizandrin,imperatorin and osthole in Qirong tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To develop an HPLC method for simultaneous determination of schizandrin,imperatorin and osthole in Qirong tablets.Methods:The analysis was performed on a Diamonsil C18 column(200 mm×4.6 mm,5 μm) with a mobile phase of methanol-water(65∶35).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃. The detection wavelength was set at 250 nm.Results:The calibration curve was linear within the range of 4-40 μg·mL-1(r=0.9997) for schizandrin,2.46-24.6 μg·mL-1(r=0.9999) for imperatorin,and 16.5-165 μg·mL-1(r=0.9997) for osthole,respectively;The recoveries(n=9) of schizandrin,imperatorin and osthole were 102.3%,101.5%,and 102.0%,respectively. Conclusion:The method is simple,accurate and selective. It can be applied to determine schizandrin,imperatorin and osthole in Qirong tablets.

Key concepts: Imperatorin, Chemistry, Chromatography, Calibration curve, High-performance liquid chromatography, Methanol, Detection limit, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC simultaneous determination of schizandrin,imperatorin and osthole in Qirong tablets — Research Paper | ScholarLens