2020•Acta chimica slovenicaOpen access

Differential Pulse Anodic Voltammetric Determination of Chlorzoxazone in Pharmaceutical Formulation using Carbon Paste Electrode

S. I. M. Zayed, Yousry M. Issa

Open full text 12 citations

Abstract

The electrochemical behavior of chlorzoxazone at the carbon paste electrode was investigated in 0.04 mol/L Britton-Robinson buffer pH 6.50 using cyclic and differential pulse voltammetric techniques. Cyclic voltammetric studies indicated that the oxidation of the drug was irreversible and controlled mainly by diffusion. Experimental and instrumental parameters were optimized (50 mV/s scan rate, 50 mV pulse amplitude, and 0.04 mol/L Britton-Robinson (BR) buffer pH 6.50 as a supporting electrolyte) and a sensitive differential pulse anodic voltammetric method has been developed for the determination of the drug over the concentration range 0.17-1.68 µg/mL chlorzoxazone, with detection and quantitation limits of 0.05 and 0.16 µg/mL, respectively. The proposed voltammetric method was successfully applied to the determination of the drug in its pharmaceutical formulation (Myoflex tablets), and in spiked human urine samples.

Open-access reader

About this research paper

What this paper is about

The electrochemical behavior of chlorzoxazone at the carbon paste electrode was investigated in 0.04 mol/L Britton-Robinson buffer pH 6.50 using cyclic and differential pulse voltammetric techniques. Cyclic voltammetric studies indicated that the oxidation of the drug was irreversible and controlled mainly by diffusion. Experimental and instrumental parameters were optimized (50 mV/s scan rate, 50 mV pulse amplitude, and 0.04 mol/L Britton-Robinson (BR) buffer pH 6.50 as a supporting electrolyte) and a sensitive differential pulse anodic voltammetric method has been developed for the determination of the drug over the concentration range 0.17-1.68 µg/mL chlorzoxazone, with detection and quantitation limits of 0.05 and 0.16 µg/mL, respectively. The proposed voltammetric method was successfully applied to the determination of the drug in its pharmaceutical formulation (Myoflex tablets), and in spiked human urine samples.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The electrochemical behavior of chlorzoxazone at the carbon paste electrode was investigated in 0.04 mol/L Britton-Robinson buffer pH 6.50 using cyclic and differential pulse voltammetric techniques. Cyclic voltammetric studies indicated that the oxidation of the drug was irreversible and controlled mainly by diffusion. Experimental and instrumental parameters were optimized (50 mV/s scan rate, 50 mV pulse amplitude, and 0.04 mol/L Britton-Robinson (BR) buffer pH 6.50 as a supporting electrolyte) and a sensitive differential pulse anodic voltammetric method has been developed for the determination of the drug over the concentration range 0.17-1.68 µg/mL chlorzoxazone, with detection and quantitation limits of 0.05 and 0.16 µg/mL, respectively. The proposed voltammetric method was successfully applied to the determination of the drug in its pharmaceutical formulation (Myoflex tablets), and in spiked human urine samples.

Key concepts: Chlorzoxazone, Horizontal scan rate, Chemistry, Supporting electrolyte, Differential pulse voltammetry, Pharmaceutical formulation, Carbon paste electrode, Buffer solution

Related papers

Back to paper searchBrowse research topicsOriginal source
Differential Pulse Anodic Voltammetric Determination of Chlorzoxazone in Pharmaceutical Formulation using Carbon Paste Electrode — Research Paper | ScholarLens