2020•Hip InternationalRequires access

Periprosthetic femoral fractures in sideways fall configuration: comparative numerical analysis of the influence of femoral stem design

Massimo Franceschini, Luigi La Barbera, Alberto Anticonome, Claudia Ottardi, Atsuki Tanaka, Tomaso Maria Tobia Villa

Open publisher page 6 citations

Abstract

INTRODUCTION: The aim of this study was to investigate the mechanisms of periprosthetic fractures occurring as a result of a sideways fall in total hip arthroplasty patients, and to compare the predictions of numerical models in terms of load distribution on the implanted femur with clinical data. MATERIALS AND METHODS: 3 numerical models were built: 1 for intact femur and 2 for implanted femur with a straight stem (resembling PBF, Permedica) and with an anatomical stem (resembling ABG II, Stryker). 4 loading configurations were simulated; 1 simulates a vertical load, and 3 simulate a fall with impact on the greater trochanter in different directions. Stress state calculated in the implanted femur was compared for the 2 models with reference to the intact case. These were compared with clinical data collected at a single centre (Istituto Ortopedico Gaetano Pini, Milan, Italy) where 41 patients were investigated after periprosthetic fracture: 26 patients had a straight uncemented stem and 15 an anatomical uncemented stem. RESULTS: The maximum calculated strain in compression in the case of ABG II implanted femur was 2 times higher than in the presence of PBF stem in the vertical loading configuration. For configurations of sideways fall, in both models, there was a progressive increase of stress state in the bone with increasing angle. Simulations of sideways fall elicited results in accordance with clinical observations: due to the peculiar stem design and consequent state of stress in the bone, anatomical stems seem to induce trochanteric fractures more frequently, while for straight stems type B fractures are more likely to occur. CONCLUSIONS: Clinical findings confirmed numerical model predictions: stem design seems to highly influence distribution of stress in the bone and consequent localisation of the fracture site.

About this research paper

What this paper is about

INTRODUCTION: The aim of this study was to investigate the mechanisms of periprosthetic fractures occurring as a result of a sideways fall in total hip arthroplasty patients, and to compare the predictions of numerical models in terms of load distribution on the implanted femur with clinical data. MATERIALS AND METHODS: 3 numerical models were built: 1 for intact femur and 2 for implanted femur with a straight stem (resembling PBF, Permedica) and with an anatomical stem (resembling ABG II, Stryker). 4 loading configurations were simulated; 1 simulates a vertical load, and 3 simulate a fall with impact on the greater trochanter in different directions. Stress state calculated in the implanted femur was compared for the 2 models with reference to the intact case. These were compared with clinical data collected at a single centre (Istituto Ortopedico Gaetano Pini, Milan, Italy) where 41 patients were investigated after periprosthetic fracture: 26 patients had a straight uncemented stem and 15 an anatomical uncemented stem. RESULTS: The maximum calculated strain in compression in the case of ABG II implanted femur was 2 times higher than in the presence of PBF stem in the vertical loading configuration. For configurations of sideways fall, in both models, there was a progressive increase of stress state in the bone with increasing angle. Simulations of sideways fall elicited results in accordance with clinical observations: due to the peculiar stem design and consequent state of stress in the bone, anatomical stems seem to induce trochanteric fractures more frequently, while for straight stems type B fractures are more likely to occur. CONCLUSIONS: Clinical findings confirmed numerical model predictions: stem design seems to highly influence distribution of stress in the bone and consequent localisation of the fracture site.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: The aim of this study was to investigate the mechanisms of periprosthetic fractures occurring as a result of a sideways fall in total hip arthroplasty patients, and to compare the predictions of numerical models in terms of load distribution on the implanted femur with clinical data. MATERIALS AND METHODS: 3 numerical models were built: 1 for intact femur and 2 for implanted femur with a straight stem (resembling PBF, Permedica) and with an anatomical stem (resembling ABG II, Stryker). 4 loading configurations were simulated; 1 simulates a vertical load, and 3 simulate a fall with impact on the greater trochanter in different directions. Stress state calculated in the implanted femur was compared for the 2 models with reference to the intact case. These were compared with clinical data collected at a single centre (Istituto Ortopedico Gaetano Pini, Milan, Italy) where 41 patients were investigated after periprosthetic fracture: 26 patients had a straight uncemented stem and 15 an anatomical uncemented stem. RESULTS: The maximum calculated strain in compression in the case of ABG II implanted femur was 2 times higher than in the presence of PBF stem in the vertical loading configuration. For configurations of sideways fall, in both models, there was a progressive increase of stress state in the bone with increasing angle. Simulations of sideways fall elicited results in accordance with clinical observations: due to the peculiar stem design and consequent state of stress in the bone, anatomical stems seem to induce trochanteric fractures more frequently, while for straight stems type B fractures are more likely to occur. CONCLUSIONS: Clinical findings confirmed numerical model predictions: stem design seems to highly influence distribution of stress in the bone and consequent localisation of the fracture site.

Key concepts: Periprosthetic, Femur, Lesser Trochanter, Medicine, Greater trochanter, Total hip arthroplasty, Orthodontics, Stress shielding

Related papers

Back to paper searchBrowse research topicsOriginal source
Periprosthetic femoral fractures in sideways fall configuration: comparative numerical analysis of the influence of femoral stem design — Research Paper | ScholarLens