2020eScholarship (California Digital Library)Requires access

Iterative X-ray spectroscopic ptychography.

Huibin Chang, Ziqin Rong, Pablo Enfedaque, Stefano Marchesini

Open publisher page 3 citations

Abstract

Spectroscopic ptychography is a powerful technique to determine the chemical composition of a sample with high spatial resolution. In spectro-ptychography, a sample is rastered through a focused X-ray beam with varying photon energy so that a series of phaseless diffraction data are recorded. Each chemical component in the material under investigation has a characteristic absorption and phase contrast as a function of photon energy. Using a dictionary formed by the set of contrast functions of each energy for each chemical component, it is possible to obtain the chemical composition of the material from high-resolution multi-spectral images. This paper presents SPA (spectroscopic ptychography with alternating direction method of multipliers), a novel algorithm to iteratively solve the spectroscopic blind ptychography problem. First, a nonlinear spectro-ptychography model based on Poisson maximum likelihood is designed, and then the proposed method is constructed on the basis of fast iterative splitting operators. SPA can be used to retrieve spectral contrast when considering either a known or an incomplete (partially known) dictionary of reference spectra. By coupling the redundancy across different spectral measurements, the proposed algorithm can achieve higher reconstruction quality when compared with standard state-of-the-art two-step methods. It is demonstrated how SPA can recover accurate chemical maps from Poisson-noised measurements, and its enhanced robustness when reconstructing reduced-redundancy ptychography data using large scanning step sizes is shown.

About this research paper

What this paper is about

Spectroscopic ptychography is a powerful technique to determine the chemical composition of a sample with high spatial resolution. In spectro-ptychography, a sample is rastered through a focused X-ray beam with varying photon energy so that a series of phaseless diffraction data are recorded. Each chemical component in the material under investigation has a characteristic absorption and phase contrast as a function of photon energy. Using a dictionary formed by the set of contrast functions of each energy for each chemical component, it is possible to obtain the chemical composition of the material from high-resolution multi-spectral images. This paper presents SPA (spectroscopic ptychography with alternating direction method of multipliers), a novel algorithm to iteratively solve the spectroscopic blind ptychography problem. First, a nonlinear spectro-ptychography model based on Poisson maximum likelihood is designed, and then the proposed method is constructed on the basis of fast iterative splitting operators. SPA can be used to retrieve spectral contrast when considering either a known or an incomplete (partially known) dictionary of reference spectra. By coupling the redundancy across different spectral measurements, the proposed algorithm can achieve higher reconstruction quality when compared with standard state-of-the-art two-step methods. It is demonstrated how SPA can recover accurate chemical maps from Poisson-noised measurements, and its enhanced robustness when reconstructing reduced-redundancy ptychography data using large scanning step sizes is shown.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Spectroscopic ptychography is a powerful technique to determine the chemical composition of a sample with high spatial resolution. In spectro-ptychography, a sample is rastered through a focused X-ray beam with varying photon energy so that a series of phaseless diffraction data are recorded. Each chemical component in the material under investigation has a characteristic absorption and phase contrast as a function of photon energy. Using a dictionary formed by the set of contrast functions of each energy for each chemical component, it is possible to obtain the chemical composition of the material from high-resolution multi-spectral images. This paper presents SPA (spectroscopic ptychography with alternating direction method of multipliers), a novel algorithm to iteratively solve the spectroscopic blind ptychography problem. First, a nonlinear spectro-ptychography model based on Poisson maximum likelihood is designed, and then the proposed method is constructed on the basis of fast iterative splitting operators. SPA can be used to retrieve spectral contrast when considering either a known or an incomplete (partially known) dictionary of reference spectra. By coupling the redundancy across different spectral measurements, the proposed algorithm can achieve higher reconstruction quality when compared with standard state-of-the-art two-step methods. It is demonstrated how SPA can recover accurate chemical maps from Poisson-noised measurements, and its enhanced robustness when reconstructing reduced-redundancy ptychography data using large scanning step sizes is shown.

Key concepts: Ptychography, Data redundancy, Redundancy (engineering), Optics, Phase retrieval, Robustness (evolution), Diffraction, Algorithm