2019•JACOWOpen access

Diagnostic Beamlines at the Solaris Storage Ring

Arkadiusz Kisiel, Stanislaw Cabala, Andrzej Marendziak, M. Ptaszkiewicz, Adriana I. Wawrzyniak, Ireneusz Zadworny, Tomasz Zbylut

Open full text 0 citations

Abstract

Precise measurement and control of the particle beam emittance is a very important input to characterize the performance of any accelerator/SRS. Beam characterizations at the SOLARIS National Synchrotron Radiation Centre are provided by two independent diagnostic beamlines called the X-ray synchrotron radiation (PINHOLE) and optical synchrotron radiation (LUMOS) beamlines, respectively. The PINHOLE beamline depicts the electron beam by analyzing the emitted X-rays. However this method is predominantly applied to the middle and high energy storage rings. At Solaris storage ring with the nominal energy of 1.5 GeV and critical photon beam energy of c.a. 2 keV, the design of the beamline was modified to provide sufficient X-ray photon flux for proper imaging. Second diagnostic beamline LUMOS will be installed and commissioned in next few months. Issues discussed include the general design philosophy, choice of instrumentation, limits to resolution, and actual performance.

About this research paper

What this paper is about

Precise measurement and control of the particle beam emittance is a very important input to characterize the performance of any accelerator/SRS. Beam characterizations at the SOLARIS National Synchrotron Radiation Centre are provided by two independent diagnostic beamlines called the X-ray synchrotron radiation (PINHOLE) and optical synchrotron radiation (LUMOS) beamlines, respectively. The PINHOLE beamline depicts the electron beam by analyzing the emitted X-rays. However this method is predominantly applied to the middle and high energy storage rings. At Solaris storage ring with the nominal energy of 1.5 GeV and critical photon beam energy of c.a. 2 keV, the design of the beamline was modified to provide sufficient X-ray photon flux for proper imaging. Second diagnostic beamline LUMOS will be installed and commissioned in next few months. Issues discussed include the general design philosophy, choice of instrumentation, limits to resolution, and actual performance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Precise measurement and control of the particle beam emittance is a very important input to characterize the performance of any accelerator/SRS. Beam characterizations at the SOLARIS National Synchrotron Radiation Centre are provided by two independent diagnostic beamlines called the X-ray synchrotron radiation (PINHOLE) and optical synchrotron radiation (LUMOS) beamlines, respectively. The PINHOLE beamline depicts the electron beam by analyzing the emitted X-rays. However this method is predominantly applied to the middle and high energy storage rings. At Solaris storage ring with the nominal energy of 1.5 GeV and critical photon beam energy of c.a. 2 keV, the design of the beamline was modified to provide sufficient X-ray photon flux for proper imaging. Second diagnostic beamline LUMOS will be installed and commissioned in next few months. Issues discussed include the general design philosophy, choice of instrumentation, limits to resolution, and actual performance.

Key concepts: Beamline, Storage ring, Synchrotron radiation, Particle accelerator, Physics, Synchrotron, Optics, Pinhole (optics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnostic Beamlines at the Solaris Storage Ring — Research Paper | ScholarLens