Experimental Performance Evaluation of an Integrated Solar-Driven Adsorption System in Terms of Thermal Storage and Cooling Capacity
M. T. Nitsas, E.G. Papoutsis, I.P. Koronaki
Abstract
Open-access reader
M. T. Nitsas, E.G. Papoutsis, I.P. Koronaki
Abstract
Open-access reader
Heat-driven coolers provide a reliable and environmentally benign alternative to traditional electrically powered chillers. Their main advantage is that they can be driven using low enthalpy heat sources. A solar system is installed at the school of Mechanical Engineering of National Technical University of Athens in order to examine the potential of thermal storage and solar cooling under Athens climatic conditions. The cooling effect is produced using a dual bed, single stage, zeolite/water adsorption chiller with cooling capacity of 10 kW at its nominal conditions of operation. Both vacuum tube collectors and hybrid photovoltaic thermal collectors are installed in order to supply the system with heat. The system is evaluated in terms of solar collectors’ useful energy production, heat stored in the intermediate buffer and cooling system’s performance. It is observed that the cooling system operates satisfactorily under Athens climatic conditions achieving a maximum cooling capacity of 3.7 kW and an average COP around 0.5.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Heat-driven coolers provide a reliable and environmentally benign alternative to traditional electrically powered chillers. Their main advantage is that they can be driven using low enthalpy heat sources. A solar system is installed at the school of Mechanical Engineering of National Technical University of Athens in order to examine the potential of thermal storage and solar cooling under Athens climatic conditions. The cooling effect is produced using a dual bed, single stage, zeolite/water adsorption chiller with cooling capacity of 10 kW at its nominal conditions of operation. Both vacuum tube collectors and hybrid photovoltaic thermal collectors are installed in order to supply the system with heat. The system is evaluated in terms of solar collectors’ useful energy production, heat stored in the intermediate buffer and cooling system’s performance. It is observed that the cooling system operates satisfactorily under Athens climatic conditions achieving a maximum cooling capacity of 3.7 kW and an average COP around 0.5.
Key concepts: Chiller, Solar air conditioning, Cooling capacity, Thermal energy storage, Nuclear engineering, Chilled water, Water cooling, Environmental science