2020Solid State TechnologyRequires access

Analysis Of G+20 Rc Building In Different Zones Using E-Tabs

J. Rex, P. Yugesh Reddy, J. Selwyn Babu

Open publisher page 6 citations

Abstract

The race towards new heights and architecture was not without difficulties. The stiffness of the structure becomes more important as the building grows in height. Because of dominating lateral loads, tall structures began to ascend higher and higher facing odd loading effects and very high loading values. Power, serviceability, stability, and human comfort are the design requirements for tall buildings. Therefore, the effects of lateral loads such as wind loads and earthquake forces are becoming increasingly significant and almost every designer faces the problem of providing sufficient strength and stability against lateral loads.The goal of this research is to study the behavior of a multi-storey R C building subjected to earthquake load through the adoption of a linear static analysis. The current research is restricted to multi-storey reinforced concrete (RC) commercial buildings with FOUR distinct zones II, III, IV & V. The review is carried out using the ETABS of FEM software. In the analysis, the building model has twenty-one levels with a constant floor height of 3 m. The effects of lateral load on moments, axial forces, shear force, base shear force, maximum floor drift and tensile forces on the structural structure are analyzed and the findings of zone 2, zone 3, zone 4 also zone 5 are also compared. Various seismic zone factor values are taken with their subsequent results be interpreted in the findings. The parameters of the construction model, such as base shear, displacements, floor drifts and floor shear, were studied and interpreted in this project

About this research paper

What this paper is about

The race towards new heights and architecture was not without difficulties. The stiffness of the structure becomes more important as the building grows in height. Because of dominating lateral loads, tall structures began to ascend higher and higher facing odd loading effects and very high loading values. Power, serviceability, stability, and human comfort are the design requirements for tall buildings. Therefore, the effects of lateral loads such as wind loads and earthquake forces are becoming increasingly significant and almost every designer faces the problem of providing sufficient strength and stability against lateral loads.The goal of this research is to study the behavior of a multi-storey R C building subjected to earthquake load through the adoption of a linear static analysis. The current research is restricted to multi-storey reinforced concrete (RC) commercial buildings with FOUR distinct zones II, III, IV & V. The review is carried out using the ETABS of FEM software. In the analysis, the building model has twenty-one levels with a constant floor height of 3 m. The effects of lateral load on moments, axial forces, shear force, base shear force, maximum floor drift and tensile forces on the structural structure are analyzed and the findings of zone 2, zone 3, zone 4 also zone 5 are also compared. Various seismic zone factor values are taken with their subsequent results be interpreted in the findings. The parameters of the construction model, such as base shear, displacements, floor drifts and floor shear, were studied and interpreted in this project

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The race towards new heights and architecture was not without difficulties. The stiffness of the structure becomes more important as the building grows in height. Because of dominating lateral loads, tall structures began to ascend higher and higher facing odd loading effects and very high loading values. Power, serviceability, stability, and human comfort are the design requirements for tall buildings. Therefore, the effects of lateral loads such as wind loads and earthquake forces are becoming increasingly significant and almost every designer faces the problem of providing sufficient strength and stability against lateral loads.The goal of this research is to study the behavior of a multi-storey R C building subjected to earthquake load through the adoption of a linear static analysis. The current research is restricted to multi-storey reinforced concrete (RC) commercial buildings with FOUR distinct zones II, III, IV & V. The review is carried out using the ETABS of FEM software. In the analysis, the building model has twenty-one levels with a constant floor height of 3 m. The effects of lateral load on moments, axial forces, shear force, base shear force, maximum floor drift and tensile forces on the structural structure are analyzed and the findings of zone 2, zone 3, zone 4 also zone 5 are also compared. Various seismic zone factor values are taken with their subsequent results be interpreted in the findings. The parameters of the construction model, such as base shear, displacements, floor drifts and floor shear, were studied and interpreted in this project

Key concepts: Serviceability (structure), Structural engineering, Structural load, Wind engineering, Shear force, Stiffness, Seismic loading, Seismic zone

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis Of G+20 Rc Building In Different Zones Using E-Tabs — Research Paper | ScholarLens