2020Journal of Advanced Research in Fluid Mechanics and Thermal SciencesOpen access

An Overview of Different Indirect and Semi-Indirect Evaporative Cooling System for Study Potency of Nanopore Skinless Bamboo as An Evaporative Cooling New Porous Material

Hendra Wijaksana, I Nyoman Suprapta Winaya, Made Sucipta, Ainul Ghurri

Open full text 7 citations

Abstract

The high energy consumption of compressor-based cooling system has prompted the researchers to study and develop non-compressor-based cooling system that less energy consumption, less environment damaging but still has high enough cooling performances. Indirect and semi indirect evaporative cooling system is the feasible non-compressor-based cooling systems that can reach the cooling performance required. These two evaporative cooling systems has some different in construction, porous material used, airflow scheme and secondary air-cooling method used for various applications. This paper would report the cooling performances achieved by those two-cooling systems in terms of cooling efficiency, cooling capacity, wet bulb effectiveness, dew point effectiveness, and temperature drop. Porous material used in indirect and semi-indirect evaporative cooling would be highlighted in terms of their type, size, thickness and any other feature. The introduction of nanopore skinless bamboo potency as a new porous material for either indirect or semi-indirect evaporative cooling would be described. In the future study of nanopore skinless bamboo, a surface morphology and several hygrothermal test including sorption, water vapor transmission, thermal conductivity test would be applied, before it utilizes as a new porous material for direct or semi indirect evaporative cooling.

About this research paper

What this paper is about

The high energy consumption of compressor-based cooling system has prompted the researchers to study and develop non-compressor-based cooling system that less energy consumption, less environment damaging but still has high enough cooling performances. Indirect and semi indirect evaporative cooling system is the feasible non-compressor-based cooling systems that can reach the cooling performance required. These two evaporative cooling systems has some different in construction, porous material used, airflow scheme and secondary air-cooling method used for various applications. This paper would report the cooling performances achieved by those two-cooling systems in terms of cooling efficiency, cooling capacity, wet bulb effectiveness, dew point effectiveness, and temperature drop. Porous material used in indirect and semi-indirect evaporative cooling would be highlighted in terms of their type, size, thickness and any other feature. The introduction of nanopore skinless bamboo potency as a new porous material for either indirect or semi-indirect evaporative cooling would be described. In the future study of nanopore skinless bamboo, a surface morphology and several hygrothermal test including sorption, water vapor transmission, thermal conductivity test would be applied, before it utilizes as a new porous material for direct or semi indirect evaporative cooling.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The high energy consumption of compressor-based cooling system has prompted the researchers to study and develop non-compressor-based cooling system that less energy consumption, less environment damaging but still has high enough cooling performances. Indirect and semi indirect evaporative cooling system is the feasible non-compressor-based cooling systems that can reach the cooling performance required. These two evaporative cooling systems has some different in construction, porous material used, airflow scheme and secondary air-cooling method used for various applications. This paper would report the cooling performances achieved by those two-cooling systems in terms of cooling efficiency, cooling capacity, wet bulb effectiveness, dew point effectiveness, and temperature drop. Porous material used in indirect and semi-indirect evaporative cooling would be highlighted in terms of their type, size, thickness and any other feature. The introduction of nanopore skinless bamboo potency as a new porous material for either indirect or semi-indirect evaporative cooling would be described. In the future study of nanopore skinless bamboo, a surface morphology and several hygrothermal test including sorption, water vapor transmission, thermal conductivity test would be applied, before it utilizes as a new porous material for direct or semi indirect evaporative cooling.

Key concepts: Evaporative cooler, Dew point, Water cooling, Materials science, Passive cooling, Cooling capacity, Desiccant, Porosity

Related papers

Back to paper searchBrowse research topicsOriginal source
An Overview of Different Indirect and Semi-Indirect Evaporative Cooling System for Study Potency of Nanopore Skinless Bamboo as An Evaporative Cooling New Porous Material — Research Paper | ScholarLens