2020International Journal of Energy ResearchOpen access

An experiment‐based validation of a system code for prediction of passive natural circulation in sodium‐cooled fast reactor

Shibao Wang, Dalin Zhang, Yapeng Liu, Chenglong Wang, Suizheng Qiu, G.H. Su, Wenxi Tian

Open full text 8 citations

Abstract

To evaluate residual heat removal capacity of next generation China sodium-cooled fast reactor (SFR) and provide data for code validation, an integral natural circulation experiment was performed on a scaled water platform which had same structure with reactor primary system. A modular code THACS focusing on safety analysis of SFR was validated by this test. Some necessary development and verification for physical property, frictional loss, and heat transfer of water were carried out first. Whole simulation of an unprotected loss-of-flow (ULOF) case was divided into two phases and computation lasted until 5000 s of test time during second stage. Agreement in light of system temperature distribution in first stage provided a suitable initial condition for subsequent transient. Satisfied flow rate curve was reproduced with decaying pressure head and valve characteristic as input when pump was stopping. All natural circulation paths were predicted, including original flow in primary loop through main pipe and reversed flow in reactor vessel cooling system (RVCS). Transition to operative mode of direct heat exchanger (DHX) in direct reactor auxiliary cooling system (DRACS) and its cooling power were also forecasted successfully. This work means a significant advance for THACS in the field of engineering application of China SFR.

Open-access reader

About this research paper

What this paper is about

To evaluate residual heat removal capacity of next generation China sodium-cooled fast reactor (SFR) and provide data for code validation, an integral natural circulation experiment was performed on a scaled water platform which had same structure with reactor primary system. A modular code THACS focusing on safety analysis of SFR was validated by this test. Some necessary development and verification for physical property, frictional loss, and heat transfer of water were carried out first. Whole simulation of an unprotected loss-of-flow (ULOF) case was divided into two phases and computation lasted until 5000 s of test time during second stage. Agreement in light of system temperature distribution in first stage provided a suitable initial condition for subsequent transient. Satisfied flow rate curve was reproduced with decaying pressure head and valve characteristic as input when pump was stopping. All natural circulation paths were predicted, including original flow in primary loop through main pipe and reversed flow in reactor vessel cooling system (RVCS). Transition to operative mode of direct heat exchanger (DHX) in direct reactor auxiliary cooling system (DRACS) and its cooling power were also forecasted successfully. This work means a significant advance for THACS in the field of engineering application of China SFR.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To evaluate residual heat removal capacity of next generation China sodium-cooled fast reactor (SFR) and provide data for code validation, an integral natural circulation experiment was performed on a scaled water platform which had same structure with reactor primary system. A modular code THACS focusing on safety analysis of SFR was validated by this test. Some necessary development and verification for physical property, frictional loss, and heat transfer of water were carried out first. Whole simulation of an unprotected loss-of-flow (ULOF) case was divided into two phases and computation lasted until 5000 s of test time during second stage. Agreement in light of system temperature distribution in first stage provided a suitable initial condition for subsequent transient. Satisfied flow rate curve was reproduced with decaying pressure head and valve characteristic as input when pump was stopping. All natural circulation paths were predicted, including original flow in primary loop through main pipe and reversed flow in reactor vessel cooling system (RVCS). Transition to operative mode of direct heat exchanger (DHX) in direct reactor auxiliary cooling system (DRACS) and its cooling power were also forecasted successfully. This work means a significant advance for THACS in the field of engineering application of China SFR.

Key concepts: Natural circulation, Nuclear engineering, Sodium-cooled fast reactor, Water cooling, Decay heat, Modular design, Heat exchanger, Transient (computer programming)

Related papers

Back to paper searchBrowse research topicsOriginal source
An experiment‐based validation of a system code for prediction of passive natural circulation in sodium‐cooled fast reactor — Research Paper | ScholarLens