2020Current Chemical BiologyRequires access

Dose Formulation, Biodistribution and PET Imaging Studies of a First-in-Class Fluorine-18 Organophosphorus Cholinesterase Inhibitor Tracer in Rat

Kiel D. Neumann, Joseph Blecha, Chih‐Kai Chao, Tony L. Huynh, Kurt R. Zinn, Henry F. VanBrocklin, Charles M. Thompson, John M. Gerdes

Open publisher page 1 citations

Abstract

Background:: To investigate dynamic live tissue organophosphorus nerve agent uptake and distribution fates resulting in acetylcholinesterase inhibition, we recently reported the first-in-class fluorine-18 [18F] radiolabeled Positron Emission Tomography (PET) imaging tracer known as [18F]O-(2-fluoroethyl)-O-(p-nitrophenyl)methylphosphonate. This tracer has been initially studied in live rats with PET imaging. Objective.: We sought to evaluate the PET tracer in vivo using a new dose formulation of saline, ethanol and L-ascorbic acid, and compare the influence of this formulation on in vivo tracer performance to previous data collected using a CH3CN:PBS formulation. Methods:: A high molar activity [18F]tracer radiosynthesis was used. Doses were formulated as saline, ethanol (≤ 1%) and L-ascorbic acid (0.1%), pH 4.0-4.5. Stability was evaluated to 6 h. Dose injection (i.v.) into male rats was followed by either ex vivo biodistribution profiling at 5, 30, 90 min, or dynamic 90 min PET imaging. Rat biodistribution and PET imaging data were compared. Results and Discussion:: An optimized radiosynthesis (8 ± 2 % RCY) resulted in stable doses for 6 h (>99%). Arterial blood included a tracer and a single metabolite. The ex vivo biodistribution and live tissue PET imaging data revealed rapid radioactivity uptake and distributed tissue levels: heart and lung, highest; liver, moderate; and brain, lowest. Conclusions:: Imaging and biodistribution data were highly correlated with expected radioactivity tissue uptake and distribution in target organs. Lower brain radioactivity levels by PET imaging were found for the new formulation (saline, 1% L-ascorbic acid, < 1% ethanol) as compared to the established CH3CN:PBS formulation. Overall, we found that the i.v. dose formulation changed the in vivo profile of an organophosphorus PET tracer that is considered an important finding for future organophosphorus PET tracer studies.

About this research paper

What this paper is about

Background:: To investigate dynamic live tissue organophosphorus nerve agent uptake and distribution fates resulting in acetylcholinesterase inhibition, we recently reported the first-in-class fluorine-18 [18F] radiolabeled Positron Emission Tomography (PET) imaging tracer known as [18F]O-(2-fluoroethyl)-O-(p-nitrophenyl)methylphosphonate. This tracer has been initially studied in live rats with PET imaging. Objective.: We sought to evaluate the PET tracer in vivo using a new dose formulation of saline, ethanol and L-ascorbic acid, and compare the influence of this formulation on in vivo tracer performance to previous data collected using a CH3CN:PBS formulation. Methods:: A high molar activity [18F]tracer radiosynthesis was used. Doses were formulated as saline, ethanol (≤ 1%) and L-ascorbic acid (0.1%), pH 4.0-4.5. Stability was evaluated to 6 h. Dose injection (i.v.) into male rats was followed by either ex vivo biodistribution profiling at 5, 30, 90 min, or dynamic 90 min PET imaging. Rat biodistribution and PET imaging data were compared. Results and Discussion:: An optimized radiosynthesis (8 ± 2 % RCY) resulted in stable doses for 6 h (>99%). Arterial blood included a tracer and a single metabolite. The ex vivo biodistribution and live tissue PET imaging data revealed rapid radioactivity uptake and distributed tissue levels: heart and lung, highest; liver, moderate; and brain, lowest. Conclusions:: Imaging and biodistribution data were highly correlated with expected radioactivity tissue uptake and distribution in target organs. Lower brain radioactivity levels by PET imaging were found for the new formulation (saline, 1% L-ascorbic acid, < 1% ethanol) as compared to the established CH3CN:PBS formulation. Overall, we found that the i.v. dose formulation changed the in vivo profile of an organophosphorus PET tracer that is considered an important finding for future organophosphorus PET tracer studies.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background:: To investigate dynamic live tissue organophosphorus nerve agent uptake and distribution fates resulting in acetylcholinesterase inhibition, we recently reported the first-in-class fluorine-18 [18F] radiolabeled Positron Emission Tomography (PET) imaging tracer known as [18F]O-(2-fluoroethyl)-O-(p-nitrophenyl)methylphosphonate. This tracer has been initially studied in live rats with PET imaging. Objective.: We sought to evaluate the PET tracer in vivo using a new dose formulation of saline, ethanol and L-ascorbic acid, and compare the influence of this formulation on in vivo tracer performance to previous data collected using a CH3CN:PBS formulation. Methods:: A high molar activity [18F]tracer radiosynthesis was used. Doses were formulated as saline, ethanol (≤ 1%) and L-ascorbic acid (0.1%), pH 4.0-4.5. Stability was evaluated to 6 h. Dose injection (i.v.) into male rats was followed by either ex vivo biodistribution profiling at 5, 30, 90 min, or dynamic 90 min PET imaging. Rat biodistribution and PET imaging data were compared. Results and Discussion:: An optimized radiosynthesis (8 ± 2 % RCY) resulted in stable doses for 6 h (>99%). Arterial blood included a tracer and a single metabolite. The ex vivo biodistribution and live tissue PET imaging data revealed rapid radioactivity uptake and distributed tissue levels: heart and lung, highest; liver, moderate; and brain, lowest. Conclusions:: Imaging and biodistribution data were highly correlated with expected radioactivity tissue uptake and distribution in target organs. Lower brain radioactivity levels by PET imaging were found for the new formulation (saline, 1% L-ascorbic acid, < 1% ethanol) as compared to the established CH3CN:PBS formulation. Overall, we found that the i.v. dose formulation changed the in vivo profile of an organophosphorus PET tracer that is considered an important finding for future organophosphorus PET tracer studies.

Key concepts: Biodistribution, Radiosynthesis, Positron emission tomography, In vivo, Chemistry, Ex vivo, Preclinical imaging, Radiochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Dose Formulation, Biodistribution and PET Imaging Studies of a First-in-Class Fluorine-18 Organophosphorus Cholinesterase Inhibitor Tracer in Rat — Research Paper | ScholarLens