2020•Medical PhysicsRequires access

Determination of the absorbed dose to water for medium‐energy x‐ray beams using Fricke dosimetry

Paulo Henrique Rosado, Camila Salata, M David, Andrea Mantuano, Arissa Pickler, Carla Lemos Mota, Carlos Eduardo de Almeida

Open publisher page 16 citations

Abstract

PURPOSE: For x-ray beams in the low and medium energy range, reference dosimetry is established in terms of air kerma. Fricke dosimetry has shown great potential in the absolute measurements of the absorbed dose to water for high-energy ranges. Therefore, the main purpose of this work was to compare the absorbed dose to water for medium-energy x-ray beams obtained through Fricke dosimetry with that obtained from the air kerma rate. METHODS: To determine the absorbed dose to water using Fricke dosimetry, the polyethylene bags methodology was chosen. Fricke solution was irradiated at four different beam qualities. The absorbed dose to water values obtained using Fricke dosimetry were compared to those obtained using the standard protocol, using the Z-score. RESULTS: Values of the Z-score were <2 for all measurements of absorbed dose to water, which means that the values obtained using Fricke dosimetry are equivalent to those obtained using the reference protocol. The combined standard uncertainty for the absorbed dose to water obtained by Fricke dosimetry was lower than that obtained with the ionization chamber. CONCLUSIONS: solution has been demonstrated to be a potential option as a standard for the quantity absorbed dose to water for medium kV x-ray qualities.

About this research paper

What this paper is about

PURPOSE: For x-ray beams in the low and medium energy range, reference dosimetry is established in terms of air kerma. Fricke dosimetry has shown great potential in the absolute measurements of the absorbed dose to water for high-energy ranges. Therefore, the main purpose of this work was to compare the absorbed dose to water for medium-energy x-ray beams obtained through Fricke dosimetry with that obtained from the air kerma rate. METHODS: To determine the absorbed dose to water using Fricke dosimetry, the polyethylene bags methodology was chosen. Fricke solution was irradiated at four different beam qualities. The absorbed dose to water values obtained using Fricke dosimetry were compared to those obtained using the standard protocol, using the Z-score. RESULTS: Values of the Z-score were <2 for all measurements of absorbed dose to water, which means that the values obtained using Fricke dosimetry are equivalent to those obtained using the reference protocol. The combined standard uncertainty for the absorbed dose to water obtained by Fricke dosimetry was lower than that obtained with the ionization chamber. CONCLUSIONS: solution has been demonstrated to be a potential option as a standard for the quantity absorbed dose to water for medium kV x-ray qualities.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: For x-ray beams in the low and medium energy range, reference dosimetry is established in terms of air kerma. Fricke dosimetry has shown great potential in the absolute measurements of the absorbed dose to water for high-energy ranges. Therefore, the main purpose of this work was to compare the absorbed dose to water for medium-energy x-ray beams obtained through Fricke dosimetry with that obtained from the air kerma rate. METHODS: To determine the absorbed dose to water using Fricke dosimetry, the polyethylene bags methodology was chosen. Fricke solution was irradiated at four different beam qualities. The absorbed dose to water values obtained using Fricke dosimetry were compared to those obtained using the standard protocol, using the Z-score. RESULTS: Values of the Z-score were <2 for all measurements of absorbed dose to water, which means that the values obtained using Fricke dosimetry are equivalent to those obtained using the reference protocol. The combined standard uncertainty for the absorbed dose to water obtained by Fricke dosimetry was lower than that obtained with the ionization chamber. CONCLUSIONS: solution has been demonstrated to be a potential option as a standard for the quantity absorbed dose to water for medium kV x-ray qualities.

Key concepts: Dosimetry, Kerma, Absorbed dose, Ionization chamber, Dose profile, Materials science, Nuclear medicine, Radiochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of the absorbed dose to water for medium‐energy x‐ray beams using Fricke dosimetry — Research Paper | ScholarLens