2019•DEStech Transactions on Computer Science and EngineeringOpen access

10-15 Frequency Stability Microwave Synthesizer for Atomic Fountain Frequency Standard

Sichen Fan, Jun Ruan, Dandan Liu, Xinliang Wang, Fan Yang, Yong Guan, Hui Zhang, Fengxiang Yu, Jun-ru SHI, Yang Bai, Shougang Zhang

Open full text 0 citations

Abstract

This paper presents the design and phase noise measurement of microwave frequency synthesizer for atomic fountain frequency standard. In this synthesizer, a voltage-controlled DRO is locked to 100MHz hydrogen maser signal through a divider chain. The required interrogation frequency 9192631770 Hz is generated by mixed with 7368230 Hz and 400 MHz signals. The experimental results show that the phase noise of interrogation signal at 9.192 GHz is -88dBc/Hz@ offset 1Hz. With such performances, the expected Dick effect contribution to atom fountain frequency standard is reported at a level of 1.0×10-15 at 1 s integrating time, that is a factor 10 higher than quantum noise limit of atom frequency standard. The carrier spectral spur of microwave synthesizer signal impacted on atomic fountain frequency standard is also discussed.

About this research paper

What this paper is about

This paper presents the design and phase noise measurement of microwave frequency synthesizer for atomic fountain frequency standard. In this synthesizer, a voltage-controlled DRO is locked to 100MHz hydrogen maser signal through a divider chain. The required interrogation frequency 9192631770 Hz is generated by mixed with 7368230 Hz and 400 MHz signals. The experimental results show that the phase noise of interrogation signal at 9.192 GHz is -88dBc/Hz@ offset 1Hz. With such performances, the expected Dick effect contribution to atom fountain frequency standard is reported at a level of 1.0×10-15 at 1 s integrating time, that is a factor 10 higher than quantum noise limit of atom frequency standard. The carrier spectral spur of microwave synthesizer signal impacted on atomic fountain frequency standard is also discussed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents the design and phase noise measurement of microwave frequency synthesizer for atomic fountain frequency standard. In this synthesizer, a voltage-controlled DRO is locked to 100MHz hydrogen maser signal through a divider chain. The required interrogation frequency 9192631770 Hz is generated by mixed with 7368230 Hz and 400 MHz signals. The experimental results show that the phase noise of interrogation signal at 9.192 GHz is -88dBc/Hz@ offset 1Hz. With such performances, the expected Dick effect contribution to atom fountain frequency standard is reported at a level of 1.0×10-15 at 1 s integrating time, that is a factor 10 higher than quantum noise limit of atom frequency standard. The carrier spectral spur of microwave synthesizer signal impacted on atomic fountain frequency standard is also discussed.

Key concepts: Frequency standard, Frequency synthesizer, Hydrogen maser, Phase noise, Atomic clock, Physics, Frequency multiplier, Frequency offset

Related papers

Back to paper searchBrowse research topicsOriginal source
10-15 Frequency Stability Microwave Synthesizer for Atomic Fountain Frequency Standard — Research Paper | ScholarLens