2020PubMedRequires access

[Determination of vitamin A and vitamin E in human serum by high performance liquid chromatography with fluorescence detection].

Ying Zhao, Jiawei Hu, Jingjun Zhao, Danyang Yin

Open publisher page 1 citations

Abstract

OBJECTIVE: To establish a method for the simultaneous and rapid determination of vitamin A and vitamin E of different configurations in human serum by high performance liquid chromatography(HPLC) with multi-wavelength fluorescence detector. METHODS: The serum was mixed after adding internal standard, and acetonitrile was added for protein precipitation. The mixture was centrifuged after extraction with n-hexane. The n-hexane layer was dried by N_2 flow, the residue was dissolved with methanol. The HPLC system was consisted of WATERS Symmetry C_(18) column(4. 6 mm × 250 mm, 5 μm) and the mobile phase was methanol. The column temperature was 30 ℃ and fluorescence detector with online wavelength conversion method was carried out for the quantitative detection. RESULTS: The liner range of determination of vitamin A, α-vitamin E, β-vitamin E and δ-vitamin E were 0. 050-2. 0 μg/mL, 0. 50-50 μg/mL, 0. 050-5. 0 μg/mL and 0. 050-5. 0 μg/mL, respectively(r≥0. 996). The minimum detection limits of the method for vitamin A and vitamin E were all 0. 02 μg/mL. The intraday and interday relative standard deviations(RSDs) were less than 3% at high, medium and low concentrations. The recoveries of the samples at the three concentrations were 91. 2%-107. 5%, and the RSDs were less than 10%. CONCLUSION: This method is simple and accurate, with higher sensitivity than using UV detector and can be used for the simultaneous determination of vitamin A and vitamin E of different configurations in serum, and is suitable for rapid detection of batch serum samples.

About this research paper

What this paper is about

OBJECTIVE: To establish a method for the simultaneous and rapid determination of vitamin A and vitamin E of different configurations in human serum by high performance liquid chromatography(HPLC) with multi-wavelength fluorescence detector. METHODS: The serum was mixed after adding internal standard, and acetonitrile was added for protein precipitation. The mixture was centrifuged after extraction with n-hexane. The n-hexane layer was dried by N_2 flow, the residue was dissolved with methanol. The HPLC system was consisted of WATERS Symmetry C_(18) column(4. 6 mm × 250 mm, 5 μm) and the mobile phase was methanol. The column temperature was 30 ℃ and fluorescence detector with online wavelength conversion method was carried out for the quantitative detection. RESULTS: The liner range of determination of vitamin A, α-vitamin E, β-vitamin E and δ-vitamin E were 0. 050-2. 0 μg/mL, 0. 50-50 μg/mL, 0. 050-5. 0 μg/mL and 0. 050-5. 0 μg/mL, respectively(r≥0. 996). The minimum detection limits of the method for vitamin A and vitamin E were all 0. 02 μg/mL. The intraday and interday relative standard deviations(RSDs) were less than 3% at high, medium and low concentrations. The recoveries of the samples at the three concentrations were 91. 2%-107. 5%, and the RSDs were less than 10%. CONCLUSION: This method is simple and accurate, with higher sensitivity than using UV detector and can be used for the simultaneous determination of vitamin A and vitamin E of different configurations in serum, and is suitable for rapid detection of batch serum samples.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish a method for the simultaneous and rapid determination of vitamin A and vitamin E of different configurations in human serum by high performance liquid chromatography(HPLC) with multi-wavelength fluorescence detector. METHODS: The serum was mixed after adding internal standard, and acetonitrile was added for protein precipitation. The mixture was centrifuged after extraction with n-hexane. The n-hexane layer was dried by N_2 flow, the residue was dissolved with methanol. The HPLC system was consisted of WATERS Symmetry C_(18) column(4. 6 mm × 250 mm, 5 μm) and the mobile phase was methanol. The column temperature was 30 ℃ and fluorescence detector with online wavelength conversion method was carried out for the quantitative detection. RESULTS: The liner range of determination of vitamin A, α-vitamin E, β-vitamin E and δ-vitamin E were 0. 050-2. 0 μg/mL, 0. 50-50 μg/mL, 0. 050-5. 0 μg/mL and 0. 050-5. 0 μg/mL, respectively(r≥0. 996). The minimum detection limits of the method for vitamin A and vitamin E were all 0. 02 μg/mL. The intraday and interday relative standard deviations(RSDs) were less than 3% at high, medium and low concentrations. The recoveries of the samples at the three concentrations were 91. 2%-107. 5%, and the RSDs were less than 10%. CONCLUSION: This method is simple and accurate, with higher sensitivity than using UV detector and can be used for the simultaneous determination of vitamin A and vitamin E of different configurations in serum, and is suitable for rapid detection of batch serum samples.

Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Hexane, Vitamin, Protein precipitation, Methanol, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of vitamin A and vitamin E in human serum by high performance liquid chromatography with fluorescence detection]. — Research Paper | ScholarLens