2020Optometry and Vision ScienceRequires access

Changes in Scleral Tonometry and Anterior Chamber Angle after Short‐term Scleral Lens Wear

Chukwuemeka Junior Obinwanne, Damian C. Echendu, Osazee Agbonlahor, Stella Dike

Open publisher page 16 citations

Abstract

SIGNIFICANCE: Scleral lens wear can alter aqueous fluid and anterior chamber angle dynamics, leading to changes in intraocular pressure (IOP). However, there is limited information supporting this relationship between scleral lens wear, anterior chamber angle (ACA), and IOP changes in an black African population. PURPOSE: The purpose of this study was to compare scleral IOP and ACA before, during, and after 4 hours of scleral lens wear in healthy neophyte scleral lens wearers from an black African population. METHODS: This was a prospective study involving 20 eyes of 20 subjects with a mean ± standard deviation age of 28.7 ± 4.3 years. The study was divided into a screening and experimental phase. Scleral lenses from a diagnostic trial set were fit on a randomly selected eye. Scleral IOP was measured using a Schiotz tonometer (Winters, Jungingen, Germany) (weight, 7.5 g) on the superior-temporal sclera, and ACA was assessed using anterior segment optical coherence tomography on the temporal angle before scleral lens wear; at 10 minutes, 2 hours, and 4 hours during wear; and 10 minutes after scleral lens removal. RESULTS: The mean ± standard deviation base curve of the scleral lens fit in the study eye was 43.4 ± 1.3 D with average tear reservoir thickness of 288.1 ± 122.0 μm at 4 hours. The mean scleral IOP before lens wear was 17.2 ± 3.5 mmHg, decreased to 16.4 ± 4.5 mmHg at 4 hours of scleral lens wear, and was 16.6 ± 3.5 mmHg 10 minutes after lens removal. The temporal ACA before scleral lens application was 43.0 ± 6.6° and varied during the 4 hours of scleral lens wear, ultimately increasing to 45.0 ± 5.4° at 10 minutes after scleral lens removal. The change in IOP and ACA was not statistically significant (F = 0.501, P = .74; and F = 2.399, P = .09, respectively). CONCLUSIONS: Results suggest that 4 hours of nonfenestrated scleral lens wear did not have a significant impact on IOP or ACA in most of our study population.

About this research paper

What this paper is about

SIGNIFICANCE: Scleral lens wear can alter aqueous fluid and anterior chamber angle dynamics, leading to changes in intraocular pressure (IOP). However, there is limited information supporting this relationship between scleral lens wear, anterior chamber angle (ACA), and IOP changes in an black African population. PURPOSE: The purpose of this study was to compare scleral IOP and ACA before, during, and after 4 hours of scleral lens wear in healthy neophyte scleral lens wearers from an black African population. METHODS: This was a prospective study involving 20 eyes of 20 subjects with a mean ± standard deviation age of 28.7 ± 4.3 years. The study was divided into a screening and experimental phase. Scleral lenses from a diagnostic trial set were fit on a randomly selected eye. Scleral IOP was measured using a Schiotz tonometer (Winters, Jungingen, Germany) (weight, 7.5 g) on the superior-temporal sclera, and ACA was assessed using anterior segment optical coherence tomography on the temporal angle before scleral lens wear; at 10 minutes, 2 hours, and 4 hours during wear; and 10 minutes after scleral lens removal. RESULTS: The mean ± standard deviation base curve of the scleral lens fit in the study eye was 43.4 ± 1.3 D with average tear reservoir thickness of 288.1 ± 122.0 μm at 4 hours. The mean scleral IOP before lens wear was 17.2 ± 3.5 mmHg, decreased to 16.4 ± 4.5 mmHg at 4 hours of scleral lens wear, and was 16.6 ± 3.5 mmHg 10 minutes after lens removal. The temporal ACA before scleral lens application was 43.0 ± 6.6° and varied during the 4 hours of scleral lens wear, ultimately increasing to 45.0 ± 5.4° at 10 minutes after scleral lens removal. The change in IOP and ACA was not statistically significant (F = 0.501, P = .74; and F = 2.399, P = .09, respectively). CONCLUSIONS: Results suggest that 4 hours of nonfenestrated scleral lens wear did not have a significant impact on IOP or ACA in most of our study population.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

SIGNIFICANCE: Scleral lens wear can alter aqueous fluid and anterior chamber angle dynamics, leading to changes in intraocular pressure (IOP). However, there is limited information supporting this relationship between scleral lens wear, anterior chamber angle (ACA), and IOP changes in an black African population. PURPOSE: The purpose of this study was to compare scleral IOP and ACA before, during, and after 4 hours of scleral lens wear in healthy neophyte scleral lens wearers from an black African population. METHODS: This was a prospective study involving 20 eyes of 20 subjects with a mean ± standard deviation age of 28.7 ± 4.3 years. The study was divided into a screening and experimental phase. Scleral lenses from a diagnostic trial set were fit on a randomly selected eye. Scleral IOP was measured using a Schiotz tonometer (Winters, Jungingen, Germany) (weight, 7.5 g) on the superior-temporal sclera, and ACA was assessed using anterior segment optical coherence tomography on the temporal angle before scleral lens wear; at 10 minutes, 2 hours, and 4 hours during wear; and 10 minutes after scleral lens removal. RESULTS: The mean ± standard deviation base curve of the scleral lens fit in the study eye was 43.4 ± 1.3 D with average tear reservoir thickness of 288.1 ± 122.0 μm at 4 hours. The mean scleral IOP before lens wear was 17.2 ± 3.5 mmHg, decreased to 16.4 ± 4.5 mmHg at 4 hours of scleral lens wear, and was 16.6 ± 3.5 mmHg 10 minutes after lens removal. The temporal ACA before scleral lens application was 43.0 ± 6.6° and varied during the 4 hours of scleral lens wear, ultimately increasing to 45.0 ± 5.4° at 10 minutes after scleral lens removal. The change in IOP and ACA was not statistically significant (F = 0.501, P = .74; and F = 2.399, P = .09, respectively). CONCLUSIONS: Results suggest that 4 hours of nonfenestrated scleral lens wear did not have a significant impact on IOP or ACA in most of our study population.

Key concepts: Scleral lens, Ophthalmology, Sclera, Medicine, Lens (geology), Intraocular pressure, Contact lens, Population

Related papers

Back to paper searchBrowse research topicsOriginal source
Changes in Scleral Tonometry and Anterior Chamber Angle after Short‐term Scleral Lens Wear — Research Paper | ScholarLens