2009PROCEEDINGS OF THE 21ST (ESV) INTERNATIONAL TECHNICAL CONFERENCE ON THE ENHANCED SAFETY OF VEHICLES, HELD JUNE 2009, STUTTGART, GERMANYRequires access

Lateral Glazing Characterization Under Head Impact: Experimental and Numerical Investigation

Marie Munsch, Nicolas Bourdet, Caroline Deck, Rémy Willinger

Open publisher page 4 citations

Abstract

In case of lateral impacts, the most frequent contact source is the side window. This window is also the most frequent aperture through which occupants are partially or fully ejected during a lateral crash. In order to keep the occupant within the vehicle during a collision, laminated side glasses have been developed to gradually replace tempered glasses. Three-layered laminated glazing is composed of two glass layers separated by a plastic PolyVinylButyral (PVB) interlayer. The aim of the present work is to improve the understanding of the side window mechanical behaviour during a head impact. An experimental study is undertaken which consists of an impact of a Hybrid III dummy head on both laminated and tempered side glazing. It appears that at same velocity, impact against laminated glass leads to a significant lower injury head risk than a tempered glass. The principal role of laminated glazing has been preserved as PVB layer never fails. A laminated side glass FE model is then proposed based on experimental validation, with the PVB interlayer implemented by an elastoplastic law with failure criteria. A parametric study is carried out to define the influence of the laminated glass mechanical characteristics on the head response. The parametric study pointed out the importance of the glass layer thickness on head responses in terms of head injury criteria. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0184.pdf For the covering abstract see ITRD E145407.

About this research paper

What this paper is about

In case of lateral impacts, the most frequent contact source is the side window. This window is also the most frequent aperture through which occupants are partially or fully ejected during a lateral crash. In order to keep the occupant within the vehicle during a collision, laminated side glasses have been developed to gradually replace tempered glasses. Three-layered laminated glazing is composed of two glass layers separated by a plastic PolyVinylButyral (PVB) interlayer. The aim of the present work is to improve the understanding of the side window mechanical behaviour during a head impact. An experimental study is undertaken which consists of an impact of a Hybrid III dummy head on both laminated and tempered side glazing. It appears that at same velocity, impact against laminated glass leads to a significant lower injury head risk than a tempered glass. The principal role of laminated glazing has been preserved as PVB layer never fails. A laminated side glass FE model is then proposed based on experimental validation, with the PVB interlayer implemented by an elastoplastic law with failure criteria. A parametric study is carried out to define the influence of the laminated glass mechanical characteristics on the head response. The parametric study pointed out the importance of the glass layer thickness on head responses in terms of head injury criteria. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0184.pdf For the covering abstract see ITRD E145407.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In case of lateral impacts, the most frequent contact source is the side window. This window is also the most frequent aperture through which occupants are partially or fully ejected during a lateral crash. In order to keep the occupant within the vehicle during a collision, laminated side glasses have been developed to gradually replace tempered glasses. Three-layered laminated glazing is composed of two glass layers separated by a plastic PolyVinylButyral (PVB) interlayer. The aim of the present work is to improve the understanding of the side window mechanical behaviour during a head impact. An experimental study is undertaken which consists of an impact of a Hybrid III dummy head on both laminated and tempered side glazing. It appears that at same velocity, impact against laminated glass leads to a significant lower injury head risk than a tempered glass. The principal role of laminated glazing has been preserved as PVB layer never fails. A laminated side glass FE model is then proposed based on experimental validation, with the PVB interlayer implemented by an elastoplastic law with failure criteria. A parametric study is carried out to define the influence of the laminated glass mechanical characteristics on the head response. The parametric study pointed out the importance of the glass layer thickness on head responses in terms of head injury criteria. The full text of this paper may be found at: http://www-nrd.nhtsa.dot.gov/pdf/esv/esv21/09-0184.pdf For the covering abstract see ITRD E145407.

Key concepts: Glazing, Laminated glass, Head (geology), Materials science, Structural engineering, Parametric statistics, Window (computing), Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
Lateral Glazing Characterization Under Head Impact: Experimental and Numerical Investigation — Research Paper | ScholarLens