2020•MaterialsOpen access

Seismic Behavior of Extended End-Plate Connections Subjected to Cyclic Loading on the Top-Side of the Column

Liang Shun Luo, Jiangui Qin, Dongzhuo Zhao, Zhiwei Steven Wu

Open full text 17 citations

Abstract

The extended end-plate connections provide excellent performance in resisting seismic loads in high-risk areas. Most scholars' experiments and finite element studies on this type of joint are focused on the method of applying displacement loads on the beam tip, while the method of applying displacement on the column side has not been the subject of further study. However, the load transmission mechanism of this type of connection is not completely consistent in actual engineering, as the design concept of "strong column weak beam" does not apply to all joints. Therefore, in this paper, the lateral displacement of the applied column is used to simulate the seismic horizontal force to study the mechanical properties of the connection joints of the "weak column and strong beam" under the limit state of earthquake action. Based on the two internal columns (IC-EP1/2) and two edge columns (EC-EP1/2), the failure modes, strength, stiffness, moment-rotation curve, skeleton curve, ductility, and energy dissipation of this type of connection were studied. Experiment results indicated that this type of connection features semi-rigid and partial strength joints. The connection rotation angle of all specimens in the test exceeds 0.05 rad, which suggests it is an ideal seismic joints. Besides, the relationship between the thickness of the end-plate and the diameter of the bolt has a greater impact on the failure mode of the joint. The finite element (FE) analysis models were established for the above connection. The numerical model was validated against experimental results and showed acceptable consistency.

About this research paper

What this paper is about

The extended end-plate connections provide excellent performance in resisting seismic loads in high-risk areas. Most scholars' experiments and finite element studies on this type of joint are focused on the method of applying displacement loads on the beam tip, while the method of applying displacement on the column side has not been the subject of further study. However, the load transmission mechanism of this type of connection is not completely consistent in actual engineering, as the design concept of "strong column weak beam" does not apply to all joints. Therefore, in this paper, the lateral displacement of the applied column is used to simulate the seismic horizontal force to study the mechanical properties of the connection joints of the "weak column and strong beam" under the limit state of earthquake action. Based on the two internal columns (IC-EP1/2) and two edge columns (EC-EP1/2), the failure modes, strength, stiffness, moment-rotation curve, skeleton curve, ductility, and energy dissipation of this type of connection were studied. Experiment results indicated that this type of connection features semi-rigid and partial strength joints. The connection rotation angle of all specimens in the test exceeds 0.05 rad, which suggests it is an ideal seismic joints. Besides, the relationship between the thickness of the end-plate and the diameter of the bolt has a greater impact on the failure mode of the joint. The finite element (FE) analysis models were established for the above connection. The numerical model was validated against experimental results and showed acceptable consistency.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The extended end-plate connections provide excellent performance in resisting seismic loads in high-risk areas. Most scholars' experiments and finite element studies on this type of joint are focused on the method of applying displacement loads on the beam tip, while the method of applying displacement on the column side has not been the subject of further study. However, the load transmission mechanism of this type of connection is not completely consistent in actual engineering, as the design concept of "strong column weak beam" does not apply to all joints. Therefore, in this paper, the lateral displacement of the applied column is used to simulate the seismic horizontal force to study the mechanical properties of the connection joints of the "weak column and strong beam" under the limit state of earthquake action. Based on the two internal columns (IC-EP1/2) and two edge columns (EC-EP1/2), the failure modes, strength, stiffness, moment-rotation curve, skeleton curve, ductility, and energy dissipation of this type of connection were studied. Experiment results indicated that this type of connection features semi-rigid and partial strength joints. The connection rotation angle of all specimens in the test exceeds 0.05 rad, which suggests it is an ideal seismic joints. Besides, the relationship between the thickness of the end-plate and the diameter of the bolt has a greater impact on the failure mode of the joint. The finite element (FE) analysis models were established for the above connection. The numerical model was validated against experimental results and showed acceptable consistency.

Key concepts: Column (typography), Materials science, Structural engineering, Composite material, Connection (principal bundle), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Seismic Behavior of Extended End-Plate Connections Subjected to Cyclic Loading on the Top-Side of the Column — Research Paper | ScholarLens