2020•Cancer Management and ResearchOpen access

Fine-Needle Aspiration of Subcentimeter Thyroid Nodules in the Real-World Management

Chaiho Jeong, Hyunsam Kim, Jeongmin Lee, Jeonghoon Ha, Min‐Hee Kim, Moo Il Kang, Dong‐Jun Lim

Open full text 4 citations

Abstract

BACKGROUND: The Korea Thyroid Association published the revised guidelines for thyroid nodules in 2016. However, whether fine-needle aspiration is accurately performed based on indications and whether the results of this procedure are appropriately addressed according to clinical guidelines, particularly in subcentimeter nodules, are unclear. METHODS: We retrospectively analyzed the fine-needle aspiration data of 331 thyroid nodules of patients who were referred to a tertiary hospital clinic for fine-needle aspiration. Each nodule was categorized according to ultrasonography findings based on the recommendations of the Korea Thyroid Association for fine-needle aspiration. Only nodules with a final pathological diagnosis of benign or malignant made using the Bethesda system were included. RESULTS: Up to 32% of thyroid nodules that were not indicated for fine-needle aspiration were aspirated. Regarding subcentimeter nodules, only 28 of 123 (22.8%) aspirated nodules were indicated for fine-needle aspiration. Of the 49 malignant subcentimeter nodules, 33 (67.3%) underwent immediate surgery. Meanwhile, 14 (28.6%) nodules were lost to follow-up, and two (4.1%) were under active surveillance. Eighteen (36.7%) malignant subcentimeter nodules were not indicated for fine-needle aspiration but underwent surgical resection instead of active surveillance. CONCLUSION: Despite the recommendations in the revised guidelines, several thyroid nodules that do not meet the indications for FNA are aspirated in real-world practice. To reduce overtreatment, a widespread knowledge of the correct indications for fine-needle aspiration is important in clinical practice, particularly for subcentimeter nodules.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The Korea Thyroid Association published the revised guidelines for thyroid nodules in 2016. However, whether fine-needle aspiration is accurately performed based on indications and whether the results of this procedure are appropriately addressed according to clinical guidelines, particularly in subcentimeter nodules, are unclear. METHODS: We retrospectively analyzed the fine-needle aspiration data of 331 thyroid nodules of patients who were referred to a tertiary hospital clinic for fine-needle aspiration. Each nodule was categorized according to ultrasonography findings based on the recommendations of the Korea Thyroid Association for fine-needle aspiration. Only nodules with a final pathological diagnosis of benign or malignant made using the Bethesda system were included. RESULTS: Up to 32% of thyroid nodules that were not indicated for fine-needle aspiration were aspirated. Regarding subcentimeter nodules, only 28 of 123 (22.8%) aspirated nodules were indicated for fine-needle aspiration. Of the 49 malignant subcentimeter nodules, 33 (67.3%) underwent immediate surgery. Meanwhile, 14 (28.6%) nodules were lost to follow-up, and two (4.1%) were under active surveillance. Eighteen (36.7%) malignant subcentimeter nodules were not indicated for fine-needle aspiration but underwent surgical resection instead of active surveillance. CONCLUSION: Despite the recommendations in the revised guidelines, several thyroid nodules that do not meet the indications for FNA are aspirated in real-world practice. To reduce overtreatment, a widespread knowledge of the correct indications for fine-needle aspiration is important in clinical practice, particularly for subcentimeter nodules.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The Korea Thyroid Association published the revised guidelines for thyroid nodules in 2016. However, whether fine-needle aspiration is accurately performed based on indications and whether the results of this procedure are appropriately addressed according to clinical guidelines, particularly in subcentimeter nodules, are unclear. METHODS: We retrospectively analyzed the fine-needle aspiration data of 331 thyroid nodules of patients who were referred to a tertiary hospital clinic for fine-needle aspiration. Each nodule was categorized according to ultrasonography findings based on the recommendations of the Korea Thyroid Association for fine-needle aspiration. Only nodules with a final pathological diagnosis of benign or malignant made using the Bethesda system were included. RESULTS: Up to 32% of thyroid nodules that were not indicated for fine-needle aspiration were aspirated. Regarding subcentimeter nodules, only 28 of 123 (22.8%) aspirated nodules were indicated for fine-needle aspiration. Of the 49 malignant subcentimeter nodules, 33 (67.3%) underwent immediate surgery. Meanwhile, 14 (28.6%) nodules were lost to follow-up, and two (4.1%) were under active surveillance. Eighteen (36.7%) malignant subcentimeter nodules were not indicated for fine-needle aspiration but underwent surgical resection instead of active surveillance. CONCLUSION: Despite the recommendations in the revised guidelines, several thyroid nodules that do not meet the indications for FNA are aspirated in real-world practice. To reduce overtreatment, a widespread knowledge of the correct indications for fine-needle aspiration is important in clinical practice, particularly for subcentimeter nodules.

Key concepts: Thyroid nodules, Medicine, Fine-needle aspiration, Nodule (geology), Thyroid, Radiology, Pathological, Ultrasonography

Related papers

Back to paper searchBrowse research topicsOriginal source
Fine-Needle Aspiration of Subcentimeter Thyroid Nodules in the Real-World Management — Research Paper | ScholarLens