2004Acta Scientiarum Naturalium Universitatis SunyatseniRequires access

Studies on Preparation and Characteristics of Monoclonal AntibodiesAgainst Enrofloxacin and Cross-Reactivity of Related Fluoroquinolones

CAIQin-ren, ZENGZhen-ling, YANGGui-xiang, CHENZhang-liu

Open publisher page 0 citations

Abstract

An ester activation method was employed to couple enrofloxacin(ENFX) to the carrier proteins BSA and OVA. The conjugates ENFX-BSA and ENFX-OVA were identified with an UV spectrophotometer and amino acid automation analysis instrument, and resulted in conjugates with 48 ENFX molecules per carrier molecule(BSA). Splenocytes from mice immunized with ENFX-BSA were fused with SP2/0 myeloma cells and hybridomas secreting antibodies against enrofloxacin were selected and cloned. Two stable monoclonal antibodies, 2C5, 5D5 of the subclass IgG2a, were isolated. Using antibody 5D5, an indirect competitive inhibition enzyme-linked immunosorbent assay (Ci-ELISA) was developed for the quantitative detection of enrofloxacin and its metabolites. The IC50 of the standard curve was 21.67 ng mL-1 and the limit of detection for enrofloxacin was 0.13 ng mL-1. This method was sensitive and had a linear range from 0.13 to 10 000 ngmL-1 (r=-0.9782). Monoclonal antibody 5D5 exhibited high relative affinity to enrofloxacin, and the cross-reactivities with ciprofloxacin,marbofloxacin, sarafloxacin and danorfloxacin were 110.8, 27.40, 71.05 and 37.41%,respectively. Three non-fluoroquinolones of cefadroxil, chloramphenicol, sulfadimethoxine were tested and there was no cross-reaction between them.

About this research paper

What this paper is about

An ester activation method was employed to couple enrofloxacin(ENFX) to the carrier proteins BSA and OVA. The conjugates ENFX-BSA and ENFX-OVA were identified with an UV spectrophotometer and amino acid automation analysis instrument, and resulted in conjugates with 48 ENFX molecules per carrier molecule(BSA). Splenocytes from mice immunized with ENFX-BSA were fused with SP2/0 myeloma cells and hybridomas secreting antibodies against enrofloxacin were selected and cloned. Two stable monoclonal antibodies, 2C5, 5D5 of the subclass IgG2a, were isolated. Using antibody 5D5, an indirect competitive inhibition enzyme-linked immunosorbent assay (Ci-ELISA) was developed for the quantitative detection of enrofloxacin and its metabolites. The IC50 of the standard curve was 21.67 ng mL-1 and the limit of detection for enrofloxacin was 0.13 ng mL-1. This method was sensitive and had a linear range from 0.13 to 10 000 ngmL-1 (r=-0.9782). Monoclonal antibody 5D5 exhibited high relative affinity to enrofloxacin, and the cross-reactivities with ciprofloxacin,marbofloxacin, sarafloxacin and danorfloxacin were 110.8, 27.40, 71.05 and 37.41%,respectively. Three non-fluoroquinolones of cefadroxil, chloramphenicol, sulfadimethoxine were tested and there was no cross-reaction between them.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ester activation method was employed to couple enrofloxacin(ENFX) to the carrier proteins BSA and OVA. The conjugates ENFX-BSA and ENFX-OVA were identified with an UV spectrophotometer and amino acid automation analysis instrument, and resulted in conjugates with 48 ENFX molecules per carrier molecule(BSA). Splenocytes from mice immunized with ENFX-BSA were fused with SP2/0 myeloma cells and hybridomas secreting antibodies against enrofloxacin were selected and cloned. Two stable monoclonal antibodies, 2C5, 5D5 of the subclass IgG2a, were isolated. Using antibody 5D5, an indirect competitive inhibition enzyme-linked immunosorbent assay (Ci-ELISA) was developed for the quantitative detection of enrofloxacin and its metabolites. The IC50 of the standard curve was 21.67 ng mL-1 and the limit of detection for enrofloxacin was 0.13 ng mL-1. This method was sensitive and had a linear range from 0.13 to 10 000 ngmL-1 (r=-0.9782). Monoclonal antibody 5D5 exhibited high relative affinity to enrofloxacin, and the cross-reactivities with ciprofloxacin,marbofloxacin, sarafloxacin and danorfloxacin were 110.8, 27.40, 71.05 and 37.41%,respectively. Three non-fluoroquinolones of cefadroxil, chloramphenicol, sulfadimethoxine were tested and there was no cross-reaction between them.

Key concepts: Enrofloxacin, Monoclonal antibody, Sulfadimethoxine, Chemistry, Antibody, Detection limit, Cross-reactivity, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Studies on Preparation and Characteristics of Monoclonal AntibodiesAgainst Enrofloxacin and Cross-Reactivity of Related Fluoroquinolones — Research Paper | ScholarLens