2020IOP Conference Series Earth and Environmental ScienceOpen access

Thermal efficiency analysis of Organic Rankine Cycle (ORC) System from low-grade heat resources using various working fluids based on simulation

Edy Hartulistiyoso, Lilis Sucahyo, Muhamad Yulianto, Mangasa Augustinus Sipahutar

Open full text 14 citations

Abstract

Abstract Thermal Efficiency of Organic Rankin Cycle (ORC) Power Plant System from low-grade heat resources using various working fluids has been analyzed based on the simulation. Four working fluids, namely R-134a, R-32, R-407A, and R-422C were selected on the simulated ORC system to determine its thermal efficiency in some temperature set up of evaporator and condenser. The working fluids are simulated with mass flow rate of 0.15 kg/s at evaporator exit temperature of 75°C, 80°C, and 85°C and at condenser exit temperature of 20°C to 50°C at each 5°C temperature difference. Fluid properties in these conditions are analyzed with REFPROP software then become data input for Cycle Tempo simulation. The thermal efficiency values of each temperature and refrigerant variation are then analyzed to obtain optimum value and variation for the simulated ORC system. The efficiency was obtained at the evaporator exit temperature of 75°C and condenser exit temperature of 45°C. ORC simulation revealed that the optimum and realistic working fluid was R-32 with thermal efficiency of 7.03 %.

About this research paper

What this paper is about

Abstract Thermal Efficiency of Organic Rankin Cycle (ORC) Power Plant System from low-grade heat resources using various working fluids has been analyzed based on the simulation. Four working fluids, namely R-134a, R-32, R-407A, and R-422C were selected on the simulated ORC system to determine its thermal efficiency in some temperature set up of evaporator and condenser. The working fluids are simulated with mass flow rate of 0.15 kg/s at evaporator exit temperature of 75°C, 80°C, and 85°C and at condenser exit temperature of 20°C to 50°C at each 5°C temperature difference. Fluid properties in these conditions are analyzed with REFPROP software then become data input for Cycle Tempo simulation. The thermal efficiency values of each temperature and refrigerant variation are then analyzed to obtain optimum value and variation for the simulated ORC system. The efficiency was obtained at the evaporator exit temperature of 75°C and condenser exit temperature of 45°C. ORC simulation revealed that the optimum and realistic working fluid was R-32 with thermal efficiency of 7.03 %.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Thermal Efficiency of Organic Rankin Cycle (ORC) Power Plant System from low-grade heat resources using various working fluids has been analyzed based on the simulation. Four working fluids, namely R-134a, R-32, R-407A, and R-422C were selected on the simulated ORC system to determine its thermal efficiency in some temperature set up of evaporator and condenser. The working fluids are simulated with mass flow rate of 0.15 kg/s at evaporator exit temperature of 75°C, 80°C, and 85°C and at condenser exit temperature of 20°C to 50°C at each 5°C temperature difference. Fluid properties in these conditions are analyzed with REFPROP software then become data input for Cycle Tempo simulation. The thermal efficiency values of each temperature and refrigerant variation are then analyzed to obtain optimum value and variation for the simulated ORC system. The efficiency was obtained at the evaporator exit temperature of 75°C and condenser exit temperature of 45°C. ORC simulation revealed that the optimum and realistic working fluid was R-32 with thermal efficiency of 7.03 %.

Key concepts: Organic Rankine cycle, Working fluid, Evaporator, Condenser (optics), Refrigerant, Thermal efficiency, Thermodynamics, Degree Rankine

Related papers

Back to paper searchBrowse research topicsOriginal source
Thermal efficiency analysis of Organic Rankine Cycle (ORC) System from low-grade heat resources using various working fluids based on simulation — Research Paper | ScholarLens