2019UMM Institutional Repository (University of Maine at Machias)Open access

PEMODELAN DAN ANALISA LONJAKAN ARUS SAAT STARTING MOTOR INDUKSI TIGA FASA MENGGUNAKAN SOLID-STATE SOFT START SWITCHING

Nahriful Asri

Open full text 2 citations

Abstract

Current starting motor that needs 6-7 times the nominal current is still big issue. Therefore we need a start motor method to overcome the overshoot current where the soft start method is an alternative to reduce the overshoot current. In this study 4 soft start tests were conducted by setting the trigger angle (alpha) at several switching stages. The soft start method of the applied three phase induction motor is able to reduce the flow of overshoot starting motor with the difference of 9 A when compared to the star-delta method. When switching 0 ° (full voltage) the value of the soft start system of a three phase induction motor can reduce to 22.7 A with a greater difference of 75 A compared to the star-delta method

Open-access reader

About this research paper

What this paper is about

Current starting motor that needs 6-7 times the nominal current is still big issue. Therefore we need a start motor method to overcome the overshoot current where the soft start method is an alternative to reduce the overshoot current. In this study 4 soft start tests were conducted by setting the trigger angle (alpha) at several switching stages. The soft start method of the applied three phase induction motor is able to reduce the flow of overshoot starting motor with the difference of 9 A when compared to the star-delta method. When switching 0 ° (full voltage) the value of the soft start system of a three phase induction motor can reduce to 22.7 A with a greater difference of 75 A compared to the star-delta method

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Current starting motor that needs 6-7 times the nominal current is still big issue. Therefore we need a start motor method to overcome the overshoot current where the soft start method is an alternative to reduce the overshoot current. In this study 4 soft start tests were conducted by setting the trigger angle (alpha) at several switching stages. The soft start method of the applied three phase induction motor is able to reduce the flow of overshoot starting motor with the difference of 9 A when compared to the star-delta method. When switching 0 ° (full voltage) the value of the soft start system of a three phase induction motor can reduce to 22.7 A with a greater difference of 75 A compared to the star-delta method

Key concepts: Overshoot (microwave communication), Motor soft starter, Current (fluid), Voltage, Control theory (sociology), Computer science, Engineering, Electrical engineering

Back to paper searchBrowse research topicsOriginal source
PEMODELAN DAN ANALISA LONJAKAN ARUS SAAT STARTING MOTOR INDUKSI TIGA FASA MENGGUNAKAN SOLID-STATE SOFT START SWITCHING — Research Paper | ScholarLens