2020Journal of Building PhysicsRequires access

CFD-CFD coupling: A novel method to develop a fast urban microclimate model

Ruijun Zhang, Parham A. Mirzaei

Open publisher page 19 citations

Abstract

Computational fluid dynamics (CFD) technique is well-known for its powerful capability of modelling the cross-ventilation. CFD is broadly coupled with energy simulation programmes, such as EnergyPlus, to expand its application in building energy calculation. During the coupling process, iterative calculation is required to improve the accuracy of the coupling method, which means the scale of the model should be designed with extra care so that the simulation can be practical in terms of computational cost. A coarse-resolution mesh (here denoted as CFD c ) cannot properly represent the required local environment to study the underlying physics. However, a fine-resolution CFD microclimate model (here denoted as CFD f ), which includes both indoor and outdoor spaces, always requires a large number of cells to capture the complexities of environment; this makes the coupling procedure a challenging problem. This study aims to propose an innovative, high-resolution and computationally cost-effective CFD f -CFD c model to overcome this gap. The full-scale CFD f works in an off-line manner at the preliminary simulation stage and generates detailed flow parameters at the interfaces for CFD c . At the dynamic stage of the simulation, CFD c participates in the coupling procedure with the other tools, for example, building energy simulation (BES) tool (e.g. EnergyPlus). The coupling of CFD f -CFD c -BES is about 200 times faster than an ordinary coupled CFD f -BES method with a significantly quicker and more stable achievement in the convergence.

About this research paper

What this paper is about

Computational fluid dynamics (CFD) technique is well-known for its powerful capability of modelling the cross-ventilation. CFD is broadly coupled with energy simulation programmes, such as EnergyPlus, to expand its application in building energy calculation. During the coupling process, iterative calculation is required to improve the accuracy of the coupling method, which means the scale of the model should be designed with extra care so that the simulation can be practical in terms of computational cost. A coarse-resolution mesh (here denoted as CFD c ) cannot properly represent the required local environment to study the underlying physics. However, a fine-resolution CFD microclimate model (here denoted as CFD f ), which includes both indoor and outdoor spaces, always requires a large number of cells to capture the complexities of environment; this makes the coupling procedure a challenging problem. This study aims to propose an innovative, high-resolution and computationally cost-effective CFD f -CFD c model to overcome this gap. The full-scale CFD f works in an off-line manner at the preliminary simulation stage and generates detailed flow parameters at the interfaces for CFD c . At the dynamic stage of the simulation, CFD c participates in the coupling procedure with the other tools, for example, building energy simulation (BES) tool (e.g. EnergyPlus). The coupling of CFD f -CFD c -BES is about 200 times faster than an ordinary coupled CFD f -BES method with a significantly quicker and more stable achievement in the convergence.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Computational fluid dynamics (CFD) technique is well-known for its powerful capability of modelling the cross-ventilation. CFD is broadly coupled with energy simulation programmes, such as EnergyPlus, to expand its application in building energy calculation. During the coupling process, iterative calculation is required to improve the accuracy of the coupling method, which means the scale of the model should be designed with extra care so that the simulation can be practical in terms of computational cost. A coarse-resolution mesh (here denoted as CFD c ) cannot properly represent the required local environment to study the underlying physics. However, a fine-resolution CFD microclimate model (here denoted as CFD f ), which includes both indoor and outdoor spaces, always requires a large number of cells to capture the complexities of environment; this makes the coupling procedure a challenging problem. This study aims to propose an innovative, high-resolution and computationally cost-effective CFD f -CFD c model to overcome this gap. The full-scale CFD f works in an off-line manner at the preliminary simulation stage and generates detailed flow parameters at the interfaces for CFD c . At the dynamic stage of the simulation, CFD c participates in the coupling procedure with the other tools, for example, building energy simulation (BES) tool (e.g. EnergyPlus). The coupling of CFD f -CFD c -BES is about 200 times faster than an ordinary coupled CFD f -BES method with a significantly quicker and more stable achievement in the convergence.

Key concepts: Computational fluid dynamics, CFD in buildings, Coupling (piping), Building energy simulation, Computer science, Simulation, Scale (ratio), Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
CFD-CFD coupling: A novel method to develop a fast urban microclimate model — Research Paper | ScholarLens