Decay heat is an important design parameter at the future Swedish spent nuclear fuel repository. It will be calculated for each fuel assembly using dedicated depletion codes, based on the operator-declared irradiation history. However, experimental verification of the calculated decay heat is also anticipated. Such verification may be obtained by gamma scanning using the established correlation between the decay heat and the emitted gamma-ray intensity from 137Cs. In this procedure, the correctness of the operator-declared fuel parameters can be verified.Recent achievements of the gamma-scanning technique include the development of a dedicated spectroscopic data-acquisition system and the use of an advanced calorimeter for calibration. Using this system, the operator-declared burnup and cooling time of 31 pressurized water reactor fuel assemblies was verified experimentally to within 2.2% (1σ) and 1.9% (1σ), respectively. The measured decay heat agreed with calorimetric data within 2.3% (1σ), whereby the calculated decay heat was verified within 2.3% (1σ). The measuring time per fuel assembly was ˜15 min.In case reliable operator-declared data are not available, the gamma-scanning technique also provides a means to independently measure the decay heat. The results obtained in this procedure agreed with calorimetric data within 2.7% (1σ).

About this research paper

What this paper is about

Decay heat is an important design parameter at the future Swedish spent nuclear fuel repository. It will be calculated for each fuel assembly using dedicated depletion codes, based on the operator-declared irradiation history. However, experimental verification of the calculated decay heat is also anticipated. Such verification may be obtained by gamma scanning using the established correlation between the decay heat and the emitted gamma-ray intensity from 137Cs. In this procedure, the correctness of the operator-declared fuel parameters can be verified.Recent achievements of the gamma-scanning technique include the development of a dedicated spectroscopic data-acquisition system and the use of an advanced calorimeter for calibration. Using this system, the operator-declared burnup and cooling time of 31 pressurized water reactor fuel assemblies was verified experimentally to within 2.2% (1σ) and 1.9% (1σ), respectively. The measured decay heat agreed with calorimetric data within 2.3% (1σ), whereby the calculated decay heat was verified within 2.3% (1σ). The measuring time per fuel assembly was ˜15 min.In case reliable operator-declared data are not available, the gamma-scanning technique also provides a means to independently measure the decay heat. The results obtained in this procedure agreed with calorimetric data within 2.7% (1σ).

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Decay heat is an important design parameter at the future Swedish spent nuclear fuel repository. It will be calculated for each fuel assembly using dedicated depletion codes, based on the operator-declared irradiation history. However, experimental verification of the calculated decay heat is also anticipated. Such verification may be obtained by gamma scanning using the established correlation between the decay heat and the emitted gamma-ray intensity from 137Cs. In this procedure, the correctness of the operator-declared fuel parameters can be verified.Recent achievements of the gamma-scanning technique include the development of a dedicated spectroscopic data-acquisition system and the use of an advanced calorimeter for calibration. Using this system, the operator-declared burnup and cooling time of 31 pressurized water reactor fuel assemblies was verified experimentally to within 2.2% (1σ) and 1.9% (1σ), respectively. The measured decay heat agreed with calorimetric data within 2.3% (1σ), whereby the calculated decay heat was verified within 2.3% (1σ). The measuring time per fuel assembly was ˜15 min.In case reliable operator-declared data are not available, the gamma-scanning technique also provides a means to independently measure the decay heat. The results obtained in this procedure agreed with calorimetric data within 2.7% (1σ).

Key concepts: Decay heat, Burnup, Nuclear engineering, Calorimeter (particle physics), Calibration, Spent nuclear fuel, Gamma ray, Nuclear data

Related papers

Back to paper searchBrowse research topicsOriginal source
Verification and Determination of the Decay Heat in Spent PWR Fuel by Means of Gamma Scanning — Research Paper | ScholarLens