2020Journal of Geotechnical and Geoenvironmental EngineeringRequires access

Pore Pressure and Kσ Evaluation at High Overburden Pressure under Field Drainage Conditions. I: Centrifuge Experiments

Min Ni, Tarek Abdoun, R. Dobry, Kaveh H. Zehtab, Alan B. Marr, Waleed El-Sekelly

Open publisher page 25 citations

Abstract

This article is the first of two companion papers studying the effect of overburden pressure on the liquefaction behavior of saturated Ottawa sand. A series of four centrifuge tests were conducted simulating a 5-m layer of this sand having two different relative densities, and subjected to overburden effective pressures of ~100 and 600 kPa (1 and 6 atm). The objective was to study the pore pressure response of the soil to base acceleration under low and high pressure, including evaluation of the overburden pressure factor Kσ for idealized field drainage conditions. The sand layer had a bottom impervious and a top pervious boundary, approximating a common field situation. A novel experimental technique was developed using a dry lead shot layer to provide the necessary high level of pressure. The performances of the sand layer under low and high confining pressure were compared in terms of times histories and profiles of excess pore pressures, cyclic stress ratios (CSR), and cyclic shear strains γc, with some of the parameters determined using system identification. It was found that pore pressure dissipation started earlier at shallower depths, and that partial drainage was more significant in the 6-atm than in the 1-atm tests. Field overburden pressure correction factors at 6 atm, Kσ, obtained from the centrifuge tests for (ru)max=0.8 in 10 cycles of shaking and including the partial drainage effect, were found to be higher than 1.0 for both Dr=45% and 80% This is different from the usual laboratory undrained Kσ<1 based on cyclic triaxial and simple shear laboratory tests and reflected in the current state of practice. The discrepancy is related to the more significant effect of partial drainage and deviation from the undrained assumption at the higher confining pressure for the field drainage and other conditions of these centrifuge tests.

About this research paper

What this paper is about

This article is the first of two companion papers studying the effect of overburden pressure on the liquefaction behavior of saturated Ottawa sand. A series of four centrifuge tests were conducted simulating a 5-m layer of this sand having two different relative densities, and subjected to overburden effective pressures of ~100 and 600 kPa (1 and 6 atm). The objective was to study the pore pressure response of the soil to base acceleration under low and high pressure, including evaluation of the overburden pressure factor Kσ for idealized field drainage conditions. The sand layer had a bottom impervious and a top pervious boundary, approximating a common field situation. A novel experimental technique was developed using a dry lead shot layer to provide the necessary high level of pressure. The performances of the sand layer under low and high confining pressure were compared in terms of times histories and profiles of excess pore pressures, cyclic stress ratios (CSR), and cyclic shear strains γc, with some of the parameters determined using system identification. It was found that pore pressure dissipation started earlier at shallower depths, and that partial drainage was more significant in the 6-atm than in the 1-atm tests. Field overburden pressure correction factors at 6 atm, Kσ, obtained from the centrifuge tests for (ru)max=0.8 in 10 cycles of shaking and including the partial drainage effect, were found to be higher than 1.0 for both Dr=45% and 80% This is different from the usual laboratory undrained Kσ<1 based on cyclic triaxial and simple shear laboratory tests and reflected in the current state of practice. The discrepancy is related to the more significant effect of partial drainage and deviation from the undrained assumption at the higher confining pressure for the field drainage and other conditions of these centrifuge tests.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article is the first of two companion papers studying the effect of overburden pressure on the liquefaction behavior of saturated Ottawa sand. A series of four centrifuge tests were conducted simulating a 5-m layer of this sand having two different relative densities, and subjected to overburden effective pressures of ~100 and 600 kPa (1 and 6 atm). The objective was to study the pore pressure response of the soil to base acceleration under low and high pressure, including evaluation of the overburden pressure factor Kσ for idealized field drainage conditions. The sand layer had a bottom impervious and a top pervious boundary, approximating a common field situation. A novel experimental technique was developed using a dry lead shot layer to provide the necessary high level of pressure. The performances of the sand layer under low and high confining pressure were compared in terms of times histories and profiles of excess pore pressures, cyclic stress ratios (CSR), and cyclic shear strains γc, with some of the parameters determined using system identification. It was found that pore pressure dissipation started earlier at shallower depths, and that partial drainage was more significant in the 6-atm than in the 1-atm tests. Field overburden pressure correction factors at 6 atm, Kσ, obtained from the centrifuge tests for (ru)max=0.8 in 10 cycles of shaking and including the partial drainage effect, were found to be higher than 1.0 for both Dr=45% and 80% This is different from the usual laboratory undrained Kσ<1 based on cyclic triaxial and simple shear laboratory tests and reflected in the current state of practice. The discrepancy is related to the more significant effect of partial drainage and deviation from the undrained assumption at the higher confining pressure for the field drainage and other conditions of these centrifuge tests.

Key concepts: Overburden, Pore water pressure, Centrifuge, Geotechnical engineering, Overburden pressure, Drainage, Geology, Liquefaction

Related papers

Back to paper searchBrowse research topicsOriginal source
Pore Pressure and Kσ Evaluation at High Overburden Pressure under Field Drainage Conditions. I: Centrifuge Experiments — Research Paper | ScholarLens