2020•Materials science forumRequires access

Study on the Modification Effect of Al-Sr Master Alloy on A356 Aluminum Alloy

Gui Qing Chen, Gaosheng Fu, Kai Huai Yang, Chao Sheng Lin

Open publisher page 2 citations

Abstract

A356 aluminum alloy was modified by Al-Sr master alloy, and the eutectic silicon phase was changed from long needle to short fiber. Compared with the untreated, the secondary dendrite spacing decreased by 14.37 %, the tensile strength increased by 13.0 MPa, and the elongation increased by 29.51 %. After modification treatment, more developed secondary dendrites and block inclusions can be seen in the tensile fracture of A356 alloy, which is not conducive to the plasticity and fatigue resistance of the alloy.

About this research paper

What this paper is about

A356 aluminum alloy was modified by Al-Sr master alloy, and the eutectic silicon phase was changed from long needle to short fiber. Compared with the untreated, the secondary dendrite spacing decreased by 14.37 %, the tensile strength increased by 13.0 MPa, and the elongation increased by 29.51 %. After modification treatment, more developed secondary dendrites and block inclusions can be seen in the tensile fracture of A356 alloy, which is not conducive to the plasticity and fatigue resistance of the alloy.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A356 aluminum alloy was modified by Al-Sr master alloy, and the eutectic silicon phase was changed from long needle to short fiber. Compared with the untreated, the secondary dendrite spacing decreased by 14.37 %, the tensile strength increased by 13.0 MPa, and the elongation increased by 29.51 %. After modification treatment, more developed secondary dendrites and block inclusions can be seen in the tensile fracture of A356 alloy, which is not conducive to the plasticity and fatigue resistance of the alloy.

Key concepts: Materials science, Alloy, Eutectic system, Elongation, Ultimate tensile strength, Aluminium, Dendrite (mathematics), Metallurgy

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Modification Effect of Al-Sr Master Alloy on A356 Aluminum Alloy — Research Paper | ScholarLens