Performance Results of a Solar Adsorption Cooling and Heating Unit
Tryfon C. Roumpedakis, Sotiriοs Karellas, Salvatore Vasta, Ursula Wittstadt, Niels Harborth
Abstract
Tryfon C. Roumpedakis, Sotiriοs Karellas, Salvatore Vasta, Ursula Wittstadt, Niels Harborth
Abstract
The high environmental impact of conventional methods of cooling and heating increased the need for renewable energy deployment for covering thermal loads.Toward that direction, the proposed system aims at offering an efficient solar powered alternative, coupling a zeolite-water adsorption chiller with a conventional vapor compression cycle.The system is designed to operate under intermittent heat supply of low-temperature solar thermal energy (<90 • C) provided by evacuated tube collectors.A prototype was developed and tested in cooling mode operation.The results from the testing of separate components showed that the adsorption chiller was operating efficiently, achieving a maximum coefficient of performance (COP) of 0.65.With respect to the combined performance of the system, evaluated on a typical week of summer in Athens, the maximum reported COP was approximately 0.575, mainly due to the lower driving temperatures with a range of 75 • C. The corresponding mean energy efficiency ratio (EER) obtained was 5.8.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The high environmental impact of conventional methods of cooling and heating increased the need for renewable energy deployment for covering thermal loads.Toward that direction, the proposed system aims at offering an efficient solar powered alternative, coupling a zeolite-water adsorption chiller with a conventional vapor compression cycle.The system is designed to operate under intermittent heat supply of low-temperature solar thermal energy (<90 • C) provided by evacuated tube collectors.A prototype was developed and tested in cooling mode operation.The results from the testing of separate components showed that the adsorption chiller was operating efficiently, achieving a maximum coefficient of performance (COP) of 0.65.With respect to the combined performance of the system, evaluated on a typical week of summer in Athens, the maximum reported COP was approximately 0.575, mainly due to the lower driving temperatures with a range of 75 • C. The corresponding mean energy efficiency ratio (EER) obtained was 5.8.
Key concepts: Unit (ring theory), Adsorption, Materials science, Nuclear engineering, Solar air conditioning, Environmental science, Computer science, Solar energy