Evaluation and Correlation of Abnormal Cell Flagging of Automated Haematology Analyzer with Peripheral Blood Film at a Hematology Laboratory in Tertiary Care Oncology Centre
Hemangi Joshi, Biren Parikh, Akash Thakkar, Manasvi Patel
Abstract
Hemangi Joshi, Biren Parikh, Akash Thakkar, Manasvi Patel
Abstract
Objectives: Automated hematology analyzer generates flags for white blood cells abnormalities, indicating associated manual peripheral blood film examination.This study was aimed at evaluation and correlation of abnormal cell flagging with manual blood film reviews to improve performance in a hematology laboratory.In this study, an automated slide maker SC-120 was used to study the performance of fully automated haematology analyzer Mindray BC-6800.Methods: Total 500 routine samples were obtained over a period of seven consecutive days, and run through analyzer which displayed flags for white blood cells.Thereby, results from flags were evaluated and correlated with smear findings through careful statistical analysis of the observed parameters.Results: Flags for white blood cells and Nucleated Red Blood Cells (NRBC) were generated by BC-6800 for 211 samples out of total 500 run samples, from which 46.45% patients were diagnosed with haematological disorder and 53.55% with solid neoplasms.Sensitivity, specificity and Youden's Index observed against total 500 samples were 100%, 99.31% and 0.99 respectively.Efficiencies for blasts, abnormal lymphocytes and atypical lymphocytes were 95.64%, 95.20% and 97.60% respectively, whereas sensitivity for blasts was 75.81%.Further, sensitivity and specificity of NRBC were 86.76% and 100% respectively.Youden's index observed for various flags was close to 1, indicating near to satisfactory performance of analyzer. Conclusion:The present study confirms that performance of an automated analyzer aligns with standard manual methodology.However, to avoid false-negative results by analyzer, peripheral smears should be examined manually.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objectives: Automated hematology analyzer generates flags for white blood cells abnormalities, indicating associated manual peripheral blood film examination.This study was aimed at evaluation and correlation of abnormal cell flagging with manual blood film reviews to improve performance in a hematology laboratory.In this study, an automated slide maker SC-120 was used to study the performance of fully automated haematology analyzer Mindray BC-6800.Methods: Total 500 routine samples were obtained over a period of seven consecutive days, and run through analyzer which displayed flags for white blood cells.Thereby, results from flags were evaluated and correlated with smear findings through careful statistical analysis of the observed parameters.Results: Flags for white blood cells and Nucleated Red Blood Cells (NRBC) were generated by BC-6800 for 211 samples out of total 500 run samples, from which 46.45% patients were diagnosed with haematological disorder and 53.55% with solid neoplasms.Sensitivity, specificity and Youden's Index observed against total 500 samples were 100%, 99.31% and 0.99 respectively.Efficiencies for blasts, abnormal lymphocytes and atypical lymphocytes were 95.64%, 95.20% and 97.60% respectively, whereas sensitivity for blasts was 75.81%.Further, sensitivity and specificity of NRBC were 86.76% and 100% respectively.Youden's index observed for various flags was close to 1, indicating near to satisfactory performance of analyzer. Conclusion:The present study confirms that performance of an automated analyzer aligns with standard manual methodology.However, to avoid false-negative results by analyzer, peripheral smears should be examined manually.
Key concepts: Hematology analyzer, Hematology, Flagging, Medicine, Internal medicine, Tertiary care, Peripheral blood, Oncology