2020PLoS ONEOpen access

Comparison of air temperature measured in a vineyard canopy and at a standard weather station

Andrés Javier Peña Quiñones, Gerrit Hoogenboom, Melba Salazar-Gutiérrez, Claudio Stöckle, Markus Keller

Open full text 18 citations

Abstract

The complex environment within a crop canopy leads to a high variability of the air temperature within the canopy, and, therefore, air temperature measured at a weather station (WS) does not represent the internal energy within a crop. The objectives of this study were to quantify the difference between the air temperature measured at a standard WS and the air temperature within a six-year-old vineyard (cv. Chardonnay) and to determine the degree of uncertainty associated with the assumption that there is no difference between the two temperatures when air temperature is used as input in grapevine models. Thermistors and thermocouples were installed within the vine canopy at heights of 0.5 m and 1.2 m above the soil surface and immediately adjacent to the berry clusters. In the middle of the clusters sensors were installed to determine the temperature of the air surrounding the clusters facing east and west. The data were recorded within the canopy from December 2015 to June 2017 as well as at the standard WS that was installed close to the vineyard (410 m). Significant differences were found between the air temperatures measured at the WS and those within the vineyard during the summer when the average daily minimum air temperature within the canopy was 1.2°C less than at the WS and the average daily maximum air temperature in the canopy was 2.0°C higher than at the WS. The mean maximum air temperature measured in the clusters facing east was 1.5°C higher and west 4.0°C higher than the temperature measured at the WS. Therefore, models that assume that air temperature measured at a weather station is similar to air temperature measured in the vineyard canopy could have greater uncertainty than models that consider the temperature within the canopy.

Open-access reader

About this research paper

What this paper is about

The complex environment within a crop canopy leads to a high variability of the air temperature within the canopy, and, therefore, air temperature measured at a weather station (WS) does not represent the internal energy within a crop. The objectives of this study were to quantify the difference between the air temperature measured at a standard WS and the air temperature within a six-year-old vineyard (cv. Chardonnay) and to determine the degree of uncertainty associated with the assumption that there is no difference between the two temperatures when air temperature is used as input in grapevine models. Thermistors and thermocouples were installed within the vine canopy at heights of 0.5 m and 1.2 m above the soil surface and immediately adjacent to the berry clusters. In the middle of the clusters sensors were installed to determine the temperature of the air surrounding the clusters facing east and west. The data were recorded within the canopy from December 2015 to June 2017 as well as at the standard WS that was installed close to the vineyard (410 m). Significant differences were found between the air temperatures measured at the WS and those within the vineyard during the summer when the average daily minimum air temperature within the canopy was 1.2°C less than at the WS and the average daily maximum air temperature in the canopy was 2.0°C higher than at the WS. The mean maximum air temperature measured in the clusters facing east was 1.5°C higher and west 4.0°C higher than the temperature measured at the WS. Therefore, models that assume that air temperature measured at a weather station is similar to air temperature measured in the vineyard canopy could have greater uncertainty than models that consider the temperature within the canopy.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The complex environment within a crop canopy leads to a high variability of the air temperature within the canopy, and, therefore, air temperature measured at a weather station (WS) does not represent the internal energy within a crop. The objectives of this study were to quantify the difference between the air temperature measured at a standard WS and the air temperature within a six-year-old vineyard (cv. Chardonnay) and to determine the degree of uncertainty associated with the assumption that there is no difference between the two temperatures when air temperature is used as input in grapevine models. Thermistors and thermocouples were installed within the vine canopy at heights of 0.5 m and 1.2 m above the soil surface and immediately adjacent to the berry clusters. In the middle of the clusters sensors were installed to determine the temperature of the air surrounding the clusters facing east and west. The data were recorded within the canopy from December 2015 to June 2017 as well as at the standard WS that was installed close to the vineyard (410 m). Significant differences were found between the air temperatures measured at the WS and those within the vineyard during the summer when the average daily minimum air temperature within the canopy was 1.2°C less than at the WS and the average daily maximum air temperature in the canopy was 2.0°C higher than at the WS. The mean maximum air temperature measured in the clusters facing east was 1.5°C higher and west 4.0°C higher than the temperature measured at the WS. Therefore, models that assume that air temperature measured at a weather station is similar to air temperature measured in the vineyard canopy could have greater uncertainty than models that consider the temperature within the canopy.

Key concepts: Vineyard, Canopy, Environmental science, Air temperature, Atmospheric sciences, Horticulture, Botany, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of air temperature measured in a vineyard canopy and at a standard weather station — Research Paper | ScholarLens