1963Unpublished venueRequires access

NATURE OF THE INTERACTION BETWEEN ELECTRONS AND WELL-DEFINED SURFACES. III. ULTRA-HIGH VACUUM SYSTEM AND SAMPLE OUTGASSING. IV. GAS SOURCE FOR THE ULTRA-HIGH VACUUM STUDY OF ADSORPTION OF KNOWN GAS LAYERS ON CLEAR SURFACES

E. L. Kern, A. G. Jackson

Open publisher page 0 citations

Abstract

The obtaining and maintaining of atomically clean surfaces is a necessary basic step in the study of well characterized surfaces. The initial part of such cleaning is to incorporate the sample and necessary measuring components in an ultra-high vacuum system, capable of maintaining a pressure of 1 x 10 to the -9th power torr (1 torr 1 mm Hg) to 1 x 10 to the -10th power torr. A double pumping arrangement, using a diffusion pump and a getter pump, with appropriate vapor trapping, valves and gauges, is described; also chamber bakeout and high-frequency heating of metal com ponents. Equipment such as liquid nitrogen and oven controllers, which provide around-the-clock maintenance, is also described. Studies of the influence of known-gas layers on a clean surface necessitates an ultra-high vacuum gas manifold system. The vacuum pumping, valving, measuring equipment and gas manifold are described. Ion gauges can be calibrated absolutely against a high vacuum McLeod gauge. By this system, capable of 1 x 10 to the -9th power to 1 x 10 to the -10th power torr, partial pressures of gases of the order of 10 to the -12th power torr can be introduced into the main testing chamber.

About this research paper

What this paper is about

The obtaining and maintaining of atomically clean surfaces is a necessary basic step in the study of well characterized surfaces. The initial part of such cleaning is to incorporate the sample and necessary measuring components in an ultra-high vacuum system, capable of maintaining a pressure of 1 x 10 to the -9th power torr (1 torr 1 mm Hg) to 1 x 10 to the -10th power torr. A double pumping arrangement, using a diffusion pump and a getter pump, with appropriate vapor trapping, valves and gauges, is described; also chamber bakeout and high-frequency heating of metal com ponents. Equipment such as liquid nitrogen and oven controllers, which provide around-the-clock maintenance, is also described. Studies of the influence of known-gas layers on a clean surface necessitates an ultra-high vacuum gas manifold system. The vacuum pumping, valving, measuring equipment and gas manifold are described. Ion gauges can be calibrated absolutely against a high vacuum McLeod gauge. By this system, capable of 1 x 10 to the -9th power to 1 x 10 to the -10th power torr, partial pressures of gases of the order of 10 to the -12th power torr can be introduced into the main testing chamber.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The obtaining and maintaining of atomically clean surfaces is a necessary basic step in the study of well characterized surfaces. The initial part of such cleaning is to incorporate the sample and necessary measuring components in an ultra-high vacuum system, capable of maintaining a pressure of 1 x 10 to the -9th power torr (1 torr 1 mm Hg) to 1 x 10 to the -10th power torr. A double pumping arrangement, using a diffusion pump and a getter pump, with appropriate vapor trapping, valves and gauges, is described; also chamber bakeout and high-frequency heating of metal com ponents. Equipment such as liquid nitrogen and oven controllers, which provide around-the-clock maintenance, is also described. Studies of the influence of known-gas layers on a clean surface necessitates an ultra-high vacuum gas manifold system. The vacuum pumping, valving, measuring equipment and gas manifold are described. Ion gauges can be calibrated absolutely against a high vacuum McLeod gauge. By this system, capable of 1 x 10 to the -9th power to 1 x 10 to the -10th power torr, partial pressures of gases of the order of 10 to the -12th power torr can be introduced into the main testing chamber.

Key concepts: Outgassing, Ultra-high vacuum, Adsorption, Electron, Sample (material), Materials science, Analytical Chemistry (journal), Atomic physics

Related papers

Back to paper searchBrowse research topicsOriginal source
NATURE OF THE INTERACTION BETWEEN ELECTRONS AND WELL-DEFINED SURFACES. III. ULTRA-HIGH VACUUM SYSTEM AND SAMPLE OUTGASSING. IV. GAS SOURCE FOR THE ULTRA-HIGH VACUUM STUDY OF ADSORPTION OF KNOWN GAS LAYERS ON CLEAR SURFACES — Research Paper | ScholarLens