Comparison of heat transfer coefficient during evaporation of natural refrigerants and R-1234yf in horizontal small tube.
Jong-Taek Oh, Kwang‐Il Choi, K. Saito
Abstract
Jong-Taek Oh, Kwang‐Il Choi, K. Saito
Abstract
An experimental data comparison of evaporation heat transfer coefficient of R-744(CO2), R-717(NH3), R-290(C3H8) and R-1234yf in horizontal small tubes was conducted under some various flow conditions. The experimental data were obtained over a heat flux range of 5–60 kW m-2, mass fluxes from 50 to 600 kg m-2 s-1, saturation temperatures from 0 to 10 °C, and quality up to 1.0. The test section made of stainless steel tubes with inner diameters of 1.5 mm and 3.0 mm, and a length of 1000 and 2000 mm, respectively, was heated uniformly by applying an electric power to the tubes directly. Effects of mass flux, heat flux, saturation temperature and inner tube diameter on heat transfer coefficient are reported in the present study. Among the present working refrigerants, R-744 has a highest heat transfer coefficient. Laminar flow was observed in the evaporative small tubes and considered in the modification of evaporation heat transfer coefficient correlations.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An experimental data comparison of evaporation heat transfer coefficient of R-744(CO2), R-717(NH3), R-290(C3H8) and R-1234yf in horizontal small tubes was conducted under some various flow conditions. The experimental data were obtained over a heat flux range of 5–60 kW m-2, mass fluxes from 50 to 600 kg m-2 s-1, saturation temperatures from 0 to 10 °C, and quality up to 1.0. The test section made of stainless steel tubes with inner diameters of 1.5 mm and 3.0 mm, and a length of 1000 and 2000 mm, respectively, was heated uniformly by applying an electric power to the tubes directly. Effects of mass flux, heat flux, saturation temperature and inner tube diameter on heat transfer coefficient are reported in the present study. Among the present working refrigerants, R-744 has a highest heat transfer coefficient. Laminar flow was observed in the evaporative small tubes and considered in the modification of evaporation heat transfer coefficient correlations.
Key concepts: Heat transfer coefficient, Thermodynamics, Heat flux, Materials science, Nucleate boiling, Evaporation, Heat transfer, Mass flux