RADIANT CEILING COOLING CHARACTERISTICS AND THERMAL COMFORT FOR OFFICE ROOMS

Ibrahim Yasin Terzioglu, Oğuz Turgut

Open publisher page 6 citations

Abstract

Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14°C, respectively.

About this research paper

What this paper is about

Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14°C, respectively.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14°C, respectively.

Key concepts: Ceiling (cloud), Radiant cooling, Thermal comfort, Environmental science, Meteorology, Architectural engineering, Materials science, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
RADIANT CEILING COOLING CHARACTERISTICS AND THERMAL COMFORT FOR OFFICE ROOMS — Research Paper | ScholarLens