2012Chin J Postgrad MedRequires access

The comparison analysis of low-dose dobutamine electrocardiography stress test and echocardiography stress test in the diagnosis of coronary artery disease

王刚强

Open publisher page 0 citations

Abstract

Objective To compare low-dose dobutamine electrocardiography (ECG) stress test and echocardiography (ECHO) stress test in the diagnosis of coronary artery disease (CHD).Methods Fifty-six patients with CHD were chosen.They were given dobutamine before test in the speed of 1 μ g/(kg· min ),and gradually increased to 5 μ g/(kg·min).Low-dose dobutamine ECG stress test,ECHO stress test and coronary angiography (CAG) were performed,and the results were compared.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test and ECHO stress test were calculated.Results CAG showed 37 cases of patients with coronary artery stenosis.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test were 62.16% (23/37),73.68% (14/19) and 66.07% (37/56).The sensitivity,specificity and accuracy of ECHO stress test were 86.49% (32/37),52.63% (10/19) and 75.00% (42/56).There were significant differences in sensitivity and specificity between two test methods (P <0.05).Conclusions In the diagnosis of CHD, low-dose dobutamine ECG stress test has high specificity,and ECHO stress test has high sensitivity and accuracy.Combination of them has high clinical value. Key words: Dobutamine;  Electrocardiography;  Echocardiography;  Coronary disease

About this research paper

What this paper is about

Objective To compare low-dose dobutamine electrocardiography (ECG) stress test and echocardiography (ECHO) stress test in the diagnosis of coronary artery disease (CHD).Methods Fifty-six patients with CHD were chosen.They were given dobutamine before test in the speed of 1 μ g/(kg· min ),and gradually increased to 5 μ g/(kg·min).Low-dose dobutamine ECG stress test,ECHO stress test and coronary angiography (CAG) were performed,and the results were compared.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test and ECHO stress test were calculated.Results CAG showed 37 cases of patients with coronary artery stenosis.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test were 62.16% (23/37),73.68% (14/19) and 66.07% (37/56).The sensitivity,specificity and accuracy of ECHO stress test were 86.49% (32/37),52.63% (10/19) and 75.00% (42/56).There were significant differences in sensitivity and specificity between two test methods (P <0.05).Conclusions In the diagnosis of CHD, low-dose dobutamine ECG stress test has high specificity,and ECHO stress test has high sensitivity and accuracy.Combination of them has high clinical value. Key words: Dobutamine;  Electrocardiography;  Echocardiography;  Coronary disease

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare low-dose dobutamine electrocardiography (ECG) stress test and echocardiography (ECHO) stress test in the diagnosis of coronary artery disease (CHD).Methods Fifty-six patients with CHD were chosen.They were given dobutamine before test in the speed of 1 μ g/(kg· min ),and gradually increased to 5 μ g/(kg·min).Low-dose dobutamine ECG stress test,ECHO stress test and coronary angiography (CAG) were performed,and the results were compared.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test and ECHO stress test were calculated.Results CAG showed 37 cases of patients with coronary artery stenosis.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test were 62.16% (23/37),73.68% (14/19) and 66.07% (37/56).The sensitivity,specificity and accuracy of ECHO stress test were 86.49% (32/37),52.63% (10/19) and 75.00% (42/56).There were significant differences in sensitivity and specificity between two test methods (P <0.05).Conclusions In the diagnosis of CHD, low-dose dobutamine ECG stress test has high specificity,and ECHO stress test has high sensitivity and accuracy.Combination of them has high clinical value. Key words: Dobutamine;  Electrocardiography;  Echocardiography;  Coronary disease

Key concepts: Dobutamine, Medicine, Coronary artery disease, Cardiology, Electrocardiography, Internal medicine, Stress Echocardiography, Stress test

Related papers

Back to paper searchBrowse research topicsOriginal source
The comparison analysis of low-dose dobutamine electrocardiography stress test and echocardiography stress test in the diagnosis of coronary artery disease — Research Paper | ScholarLens