The comparison analysis of low-dose dobutamine electrocardiography stress test and echocardiography stress test in the diagnosis of coronary artery disease
王刚强
Abstract
王刚强
Abstract
Objective To compare low-dose dobutamine electrocardiography (ECG) stress test and echocardiography (ECHO) stress test in the diagnosis of coronary artery disease (CHD).Methods Fifty-six patients with CHD were chosen.They were given dobutamine before test in the speed of 1 μ g/(kg· min ),and gradually increased to 5 μ g/(kg·min).Low-dose dobutamine ECG stress test,ECHO stress test and coronary angiography (CAG) were performed,and the results were compared.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test and ECHO stress test were calculated.Results CAG showed 37 cases of patients with coronary artery stenosis.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test were 62.16% (23/37),73.68% (14/19) and 66.07% (37/56).The sensitivity,specificity and accuracy of ECHO stress test were 86.49% (32/37),52.63% (10/19) and 75.00% (42/56).There were significant differences in sensitivity and specificity between two test methods (P <0.05).Conclusions In the diagnosis of CHD, low-dose dobutamine ECG stress test has high specificity,and ECHO stress test has high sensitivity and accuracy.Combination of them has high clinical value. Key words: Dobutamine; Electrocardiography; Echocardiography; Coronary disease
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To compare low-dose dobutamine electrocardiography (ECG) stress test and echocardiography (ECHO) stress test in the diagnosis of coronary artery disease (CHD).Methods Fifty-six patients with CHD were chosen.They were given dobutamine before test in the speed of 1 μ g/(kg· min ),and gradually increased to 5 μ g/(kg·min).Low-dose dobutamine ECG stress test,ECHO stress test and coronary angiography (CAG) were performed,and the results were compared.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test and ECHO stress test were calculated.Results CAG showed 37 cases of patients with coronary artery stenosis.The sensitivity,specificity and accuracy of low-dose dobutamine ECG stress test were 62.16% (23/37),73.68% (14/19) and 66.07% (37/56).The sensitivity,specificity and accuracy of ECHO stress test were 86.49% (32/37),52.63% (10/19) and 75.00% (42/56).There were significant differences in sensitivity and specificity between two test methods (P <0.05).Conclusions In the diagnosis of CHD, low-dose dobutamine ECG stress test has high specificity,and ECHO stress test has high sensitivity and accuracy.Combination of them has high clinical value. Key words: Dobutamine; Electrocardiography; Echocardiography; Coronary disease
Key concepts: Dobutamine, Medicine, Coronary artery disease, Cardiology, Electrocardiography, Internal medicine, Stress Echocardiography, Stress test