2019Zhonghua chuangshang guke zazhiRequires access

Progress in research on infra-acetabular screwing for acetabular fracture

Fei Liu, Jie Xiang

Open publisher page 0 citations

Abstract

Surgical treatment of acetabular fracture is very challenging because the acetabular geometry is complex. As anterior and posterior columns are the main support structures of the acetabulum, anatomical reduction and strong internal fixation of the two acetabular columns can achieve the best prognosis for patients with acetabular fracture. Constant study of the complex anatomy around the acetabulum reveals an infra-acetabular screw channel that can pass through both columns. Biomechanical studies show that use of an additional infra-acetabular screw can greatly strengthen the internal fixation of acetabular fracture. Biomor-phological studies prove that an infra-acetabular screw channel of 5 mm in diameter is available in more than 90% of people which allows insertion of a 3.5 mm screw. Imaging studies demonstrate that one in-fra-acetabular screw can be safely placed under the guidance of C-arm roentgenography. In surgery of acetabular fracture, surgeons have used infra-acetabular screws, the clinical value of which has been confirmed by good functional recovery of the patients after surgery. This paper presents an overview of the progress in research on infra-acetabular screwing for acetabular fracture. Key words: Acetabulum; Fractures, bone; Bone nails; Fracture fixation, internal

About this research paper

What this paper is about

Surgical treatment of acetabular fracture is very challenging because the acetabular geometry is complex. As anterior and posterior columns are the main support structures of the acetabulum, anatomical reduction and strong internal fixation of the two acetabular columns can achieve the best prognosis for patients with acetabular fracture. Constant study of the complex anatomy around the acetabulum reveals an infra-acetabular screw channel that can pass through both columns. Biomechanical studies show that use of an additional infra-acetabular screw can greatly strengthen the internal fixation of acetabular fracture. Biomor-phological studies prove that an infra-acetabular screw channel of 5 mm in diameter is available in more than 90% of people which allows insertion of a 3.5 mm screw. Imaging studies demonstrate that one in-fra-acetabular screw can be safely placed under the guidance of C-arm roentgenography. In surgery of acetabular fracture, surgeons have used infra-acetabular screws, the clinical value of which has been confirmed by good functional recovery of the patients after surgery. This paper presents an overview of the progress in research on infra-acetabular screwing for acetabular fracture. Key words: Acetabulum; Fractures, bone; Bone nails; Fracture fixation, internal

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Surgical treatment of acetabular fracture is very challenging because the acetabular geometry is complex. As anterior and posterior columns are the main support structures of the acetabulum, anatomical reduction and strong internal fixation of the two acetabular columns can achieve the best prognosis for patients with acetabular fracture. Constant study of the complex anatomy around the acetabulum reveals an infra-acetabular screw channel that can pass through both columns. Biomechanical studies show that use of an additional infra-acetabular screw can greatly strengthen the internal fixation of acetabular fracture. Biomor-phological studies prove that an infra-acetabular screw channel of 5 mm in diameter is available in more than 90% of people which allows insertion of a 3.5 mm screw. Imaging studies demonstrate that one in-fra-acetabular screw can be safely placed under the guidance of C-arm roentgenography. In surgery of acetabular fracture, surgeons have used infra-acetabular screws, the clinical value of which has been confirmed by good functional recovery of the patients after surgery. This paper presents an overview of the progress in research on infra-acetabular screwing for acetabular fracture. Key words: Acetabulum; Fractures, bone; Bone nails; Fracture fixation, internal

Key concepts: Acetabulum, Acetabular fracture, Medicine, Internal fixation, Fixation (population genetics), Reduction (mathematics), Orthodontics, Radiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Progress in research on infra-acetabular screwing for acetabular fracture — Research Paper | ScholarLens